4.10 Parameters: 9-** PROFIdrive9-00 SetpointRange: Function:0* [0 - 65535 ]9-07 Actual ValueRange: Function:0* [0 - 65535 ]9-15 PCD Write ConfigurationOption: Function:[0][302] Minimum Reference[303] Maximum Reference[312] Catch up/slow Down Value[341] Ramp 1 Ramp Up Time[342] Ramp 1 Ramp Down Time[351] Ramp 2 Ramp Up Time[352] Ramp 2 Ramp Down Time[380] Jog Ramp Time[381] Quick Stop Ramp Time[412] Motor Speed Low Limit [Hz][414] Motor Speed High Limit [Hz][416] Torque Limit Motor Mode[417] Torque Limit Generator Mode[553] Term. 29 High Ref./Feedb. Value[558] Term. 33 High Ref./Feedb. Value[590] Digital & Relay Bus Control[593] Pulse Out 27 Bus Control[595] Pulse Out 29 Bus Control[615] Terminal 53 High Ref./Feedb. Value[625] Terminal 54 High Ref./Feedb. Value[696] Terminal 42 Output Bus Control[748] PCD Feed Forward[890] Bus Jog 1 Speed[891] Bus Jog 2 Speed[1680] Fieldbus CTW 1[1682] Fieldbus REF 19-16 PCD Read ConfigurationOption: Function:[0][1500] Operating hours[1501] Running Hours[1502] kWh Counter[1600] Control Word[1601] Reference [Unit][1602] Reference [%][1603] Status Word[1605] Main Actual Value [%][1609] Custom Readout[1610] Power [kW][1611] Power [hp][1612] Motor Voltage9-16 PCD Read ConfigurationOption: Function:[1613] Frequency[1614] Motor current[1615] Frequency [%][1616] Torque [Nm][1618] Motor Thermal[1622] Torque [%][1630] DC Link Voltage[1633] Brake Energy /2 min[1634] Heatsink Temp.[1635] Inverter Thermal[1638] SL Controller State[1639] Control Card Temp.[1650] External Reference[1652] Feedback[Unit][1653] Digi Pot Reference[1657] Feedback [RPM][1660] Digital Input[1661] Terminal 53 Setting[1662] Analog Input 53[1663] Terminal 54 Setting[1664] Analog Input AI54[1665] Analog Output 42 [mA][1667] Pulse Input 29[Hz][1668] Pulse Input 33 [Hz][1669] Pulse Output 27 [Hz][1670] Pulse Output 29 [Hz][1671] Relay Output[1672] Counter A[1673] Counter B[1679] Analog Output AO45[1684] Comm. Option STW[1685] FC Port CTW 1[1690] Alarm Word[1691] Alarm Word 2[1692] Warning Word[1693] Warning Word 2[1694] Ext. Status Word[1695] Ext. Status Word 29-18 Node AddressRange: Function:126* [ 0 -126 ]Enter the station address in this parameter oralternatively in the hardware switch. To adjust thestation address in parameter 9-18 Node Address,set the hardware switch to 126 or 127 (i.e. allswitches set to ‘on’). Otherwise this parameterdisplays the actual setting of the switch.9-19 Drive Unit System NumberRange: Function:1037* [0 - 65535 ]Parameter Descriptions Programming Guide74 Danfoss A/S © Rev. 2014-03-31 All rights reserved. MG06C40244