Chapter 1 TroubleshootingVersion 4 2008.01.17FIP-1. 55 Close FrontCover 077-300Are there anydamages on theCOVER ASSYFRONT?NoYesPossible causative parts:COVER ASSY FRONT (PL1.2.98)HARN ASSY INTERLOCK (PL9.1.3)LVPS (PL9.1.4)PWBA MCU (PL9.1.20)Checking COVER ASSYFRONT for shape.Checking the interlockswitch for operation.Replace the COVERASSY FRONT.(Removal 17/Replacement 29)NoYesReplace the PWBAMCU. (Removal 29/Replacement 17)Checking after replacingthe HARN ASSYINTERLOCK.Replace the HARN ASSYINTERLOCK. (Removal35/Replacement 11)Does the error stilloccur when turningon the power?NoYesENDDoes the number on the screenincrease by one, every time theFront Cover is operated?Checked by [Digital Input] - [DI-7]in [IOT Diagnosis].Checking after replacing theLVPSReplace the LVPS. (Removal33/Replacement 13)Does the error stilloccur when turningon the power?NoYesENDReplace the PWBAMCU. (Removal 29/Replacement 17)