2 - 41Chapter 2 Operation of Diag.Version 3 2007.03.15Dup Clutch (DO-35)1) Turn on the power and enter the Diagnostic Mode.2) Execute the DO-35. Upon hitting the "return" key, the operat-ing noise of the clutch will be heard.3) Press the "Cancel" key to stop the clutch.Combination test is as follows.NOTE: The duplex gear rotates when the DO-13 and the DO-35 areexecuted. This procedure is for the technical staff.When performing operation for five minutes or longer with the frontcover open, remove all toner cartridges, and cover the drum to avoidexposure to light.1) Turn on the power and enter the Diagnostic Mode.2) Open the Front Cover.3) Cheat the safety Interlock System.4) Execute the DO-13 and the DO-35.5) Confirm the gear rotation.6) Press the "Cancel" key to stop the clutch.7) Press the "T" key to display the DO-13.8) Press the "Cancel" key to stop the motor.9) Remove the cheater and close the Front Cover.Clutch and Solenoid name(Diag. Code) Confirmation procedureKmy02034KA