2 - 37Chapter 2 Operation of Diag.Version 1 2006.02.03MPF Turn Clutch (DO-2b)1) Turn on the power and enter the Diagnostic Mode.2) Execute the DO-2b. Upon hitting the "return" key, the operat-ing noise of the clutch will be heard.3) Press the "Cancel" key to stop the clutch.Combination test is as follows.NOTE: The MPF turn roll rotates when the DO-a and the DO-2b areexecuted. This procedure is for the technical staff.1) Turn on the power and enter the Diagnostic Mode.2) Remove the Tray 1 paper cassette.3) Execute the DO-a and the DO-2b.4) Confirm the Turn Roll rotation.5) Press the "Cancel" key to stop the clutch.6) Press the "T" key to display the DO-a.7) Press the "Cancel" key to stop the motor.8) Replace the Tray 1 paper cassette.MPF Feed Solenoid (DO-2d)1) Turn on the power and enter the Diagnostic Mode.2) Execute the DO-2d. Upon hitting the "return" key, the operat-ing noise of the solenoid will be heard.3) Press the "Cancel" key to stop the solenoid.Combination test is as follows.NOTE: The MPF feed roll rotates when the DO-a and the DO-2d areexecuted. This procedure is for the technical staff.1) Turn on the power and enter the Diagnostic Mode.2) Remove the Tray 1 paper cassette.3) Execute the DO-a and the DO-2d.4) Confirm the Feed Roll rotation.5) Press the "Cancel" key to stop the clutch.6) Press the "T" key to display the DO-a.7) Press the "Cancel" key to stop the motor.8) Replace the Tray 1 paper cassette.Clutch and Solenoid name(Diag. Code) Confirmation procedureKmy02029KAMPF Turn RollKmy02030KAMPF Feed Roll