CHAPTER 5: SETTINGS FLEXLOGICC70 CAPACITOR BANK PROTECTION AND CONTROL SYSTEM – INSTRUCTION MANUAL 5-1675ELEMENT:Breaker restrikeBRK RESTRIKE 1 OPBRK RESTRIKE 1 OP ABRK RESTRIKE 1 OP BBRK RESTRIKE 1 OP CBreaker restrike detected in any phase of the breaker control 1 elementBreaker restrike detected in phase A of the breaker control 1 elementBreaker restrike detected in phase B of the breaker control 1 elementBreaker restrike detected in phase C of the breaker control 1 elementBKR RESTRIKE 2 to 3 Same set of operands as shown for BKR RESTRIKE 1ELEMENT:Breaker controlBREAKER 1 OFF CMDBREAKER 1 ON CMDBREAKER 1 ΦA BAD STBREAKER 1 ΦA INTERMBREAKER 1 ΦA CLSDBREAKER 1 ΦA OPENBREAKER 1 ΦB BAD STBREAKER 1 ΦB INTERMBREAKER 1 ΦB CLSDBREAKER 1 ΦB OPENBREAKER 1 ΦC BAD STBREAKER 1 ΦC INTERMBREAKER 1 ΦC CLSDBREAKER 1 ΦC OPENBREAKER 1 BAD STATUSBREAKER 1 CLOSEDBREAKER 1 OPENBREAKER 1 DISCREPBREAKER 1 TROUBLEBREAKER 1 MNL OPENBREAKER 1 MNL CLSBREAKER 1 TRIP ABREAKER 1 TRIP BBREAKER 1 TRIP CBREAKER 1 ANY P OPENBREAKER 1 ONE P OPENBREAKER 1 OOSBREAKER 1 TAG ONBREAKER 1 TAG OFFBREAKER 1 SUBD CLSDBREAKER 1 SUBD OPENBREAKER 1 BYPASS ONBREAKER 1 BYPASS OFFBREAKER 1 BLK RCLSBREAKER 1 ENA RCLSBreaker 1 3-pole open command/trip initiatedBreaker 1 close command initiatedBreaker 1 phase A bad status is detected (discrepancy between the 52/a and52/b contacts)Breaker 1 phase A intermediate status is detected (transition from oneposition to another)Breaker 1 phase A is closedBreaker 1 phase A is openBreaker 1 phase B bad status is detected (discrepancy between the 52/a and52/b contacts)Breaker 1 phase B intermediate status is detected (transition from oneposition to another)Breaker 1 phase B is closedBreaker 1 phase B is openBreaker 1 phase C bad status is detected (discrepancy between the 52/a and52/b contacts)Breaker 1 phase C intermediate status is detected (transition from oneposition to another)Breaker 1 phase C is closedBreaker 1 phase C is openBreaker 1 bad status is detected on any poleBreaker 1 is closedBreaker 1 is openBreaker 1 has discrepancyBreaker 1 trouble alarmBreaker 1 manual openBreaker 1 manual closeBreaker 1 trip phase A commandBreaker 1 trip phase B commandBreaker 1 trip phase C commandAt least one pole of breaker 1 is openOnly one pole of breaker 1 is openBreaker 1 is out of serviceBreaker 1 tagged so manual trip and close and autoreclose are blockedBreaker 1 not taggedBreaker 1 status manually substituted to closedBreaker 1 status manually substituted to openBreaker 1 control interlocking is manually bypassedBreaker 1 control interlocking is not manually bypassedBreaker 1 command to manually block autorecloseBreaker 1 command to manually enable autorecloseBREAKER 2 to 3 Same set of operands as shown for BREAKER 1ELEMENT:Capacitor controlCAP 1 IN REMOTECAP 1 IN LOCALCAP 1 IN AUTOCAP 1 IN MANCAP 1 DISCHARGINGCAP 1 BKR TRIPCAP 1 BKR CLOSECapacitor control element 1 in remote control modeCapacitor control element 1 in local control modeCapacitor control element 1 in automatic modeCapacitor control element 1 in manual modeCapacitor 1 is discharging; asserted till discharge delay expiresCapacitor 1 breaker trip commandCapacitor 1 breaker close commandCAP 2 to 3 Same set of operands as shown for CAP 1ELEMENT:Digital countersCounter 1 HICounter 1 EQLCounter 1 LODigital counter 1 output is ‘more than’ comparison valueDigital counter 1 output is ‘equal to’ comparison valueDigital counter 1 output is ‘less than’ comparison valueCounter 2 to 8 Same set of operands as shown for Counter 1Operand type Operand syntax Operand description