GE Multilin D30 Line Distance Protection System B-13APPENDIX B B.4 MEMORY MAPPINGB1C02 Source 1 Phase A Real Power -1000000000000 to1000000000000W 0.001 F060 01C04 Source 1 Phase B Real Power -1000000000000 to1000000000000W 0.001 F060 01C06 Source 1 Phase C Real Power -1000000000000 to1000000000000W 0.001 F060 01C08 Source 1 Three Phase Reactive Power -1000000000000 to1000000000000var 0.001 F060 01C0A Source 1 Phase A Reactive Power -1000000000000 to1000000000000var 0.001 F060 01C0C Source 1 Phase B Reactive Power -1000000000000 to1000000000000var 0.001 F060 01C0E Source 1 Phase C Reactive Power -1000000000000 to1000000000000var 0.001 F060 01C10 Source 1 Three Phase Apparent Power -1000000000000 to1000000000000VA 0.001 F060 01C12 Source 1 Phase A Apparent Power -1000000000000 to1000000000000VA 0.001 F060 01C14 Source 1 Phase B Apparent Power -1000000000000 to1000000000000VA 0.001 F060 01C16 Source 1 Phase C Apparent Power -1000000000000 to1000000000000VA 0.001 F060 01C18 Source 1 Three Phase Power Factor -0.999 to 1 --- 0.001 F013 01C19 Source 1 Phase A Power Factor -0.999 to 1 --- 0.001 F013 01C1A Source 1 Phase B Power Factor -0.999 to 1 --- 0.001 F013 01C1B Source 1 Phase C Power Factor -0.999 to 1 --- 0.001 F013 01C1C Reserved (4 items) --- --- --- F001 01C20 ...Repeated for Source 21C40 ...Repeated for Source 31C60 ...Repeated for Source 41C80 ...Repeated for Source 51CA0 ...Repeated for Source 6Source Frequency (Read Only) (6 modules)1D80 Frequency for Source 1 --- Hz --- F003 01D82 Frequency for Source 2 --- Hz --- F003 01D84 Frequency for Source 3 --- Hz --- F003 01D86 Frequency for Source 4 --- Hz --- F003 01D88 Frequency for Source 5 --- Hz --- F003 01D8A Frequency for Source 6 --- Hz --- F003 0Breaker Arcing Current Actuals (Read Only Non-Volatile) (2 modules)21E0 Breaker 1 Arcing Current Phase A 0 to 99999999 kA2 -cyc 1 F060 021E2 Breaker 1 Arcing Current Phase B 0 to 99999999 kA2 -cyc 1 F060 021E4 Breaker 1 Arcing Current Phase C 0 to 99999999 kA2 -cyc 1 F060 021E6 Breaker 1 Operating Time Phase A 0 to 65535 ms 1 F001 021E7 Breaker 1 Operating Time Phase B 0 to 65535 ms 1 F001 021E8 Breaker 1 Operating Time Phase C 0 to 65535 ms 1 F001 021E9 Breaker 1 Operating Time 0 to 65535 ms 1 F001 021EA ...Repeated for Breaker Arcing Current 2Breaker Arcing Current Commands (Read/Write Command) (2 modules)2224 Breaker 1 Arcing Current Clear Command 0 to 1 --- 1 F126 0 (No)2225 Breaker 2 Arcing Current Clear Command 0 to 1 --- 1 F126 0 (No)Passwords Unauthorized Access (Read/Write Command)2230 Reset Unauthorized Access 0 to 1 --- 1 F126 0 (No)Fault Location (Read Only) (5 modules)2340 Fault 1 Prefault Phase A Current Magnitude 0 to 999999.999 A 0.001 F060 02342 Fault 1 Prefault Phase A Current Angle -359.9 to 0 degrees 0.1 F002 02343 Fault 1 Prefault Phase B Current Magnitude 0 to 999999.999 A 0.001 F060 02345 Fault 1 Prefault Phase B Current Angle -359.9 to 0 degrees 0.1 F002 0Table B–9: MODBUS MEMORY MAP (Sheet 5 of 51)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT