GE Multilin D30 Line Distance Protection System B-23APPENDIX B B.4 MEMORY MAPPINGB3CDA ...Repeated for Field Contact Output 63D1C ...Repeated for Field Contact Output 73D5E ...Repeated for Field Contact Output 8Field Unit Latching Outputs (Read/Write Setting) (8 modules)3DC7 Field Latching Output 1 ID 0 to 1 --- --- F205 "FLO Ux /LO"3DCD Field Latching Output 1 Open 0 to 4294967295 --- 1 F300 03DCF Field Latching Output 1 Close 0 to 4294967295 --- 1 F300 03DD1 Field Latching Output 1 Events 0 to 1 --- 1 F102 1 (Enabled)3DD2 Field Latching Output 1 Reserved (2 items) 0 to 1 --- 1 F001 03DD4 ...Repeated for Fielding Latching Output 23DE1 ...Repeated for Field Contact Output 33DEE ...Repeated for Field Contact Output 43DFB ...Repeated for Field Contact Output 53E08 ...Repeated for Field Contact Output 63E15 ...Repeated for Field Contact Output 73E22 ...Repeated for Field Contact Output 8Field Unit Shared Outputs (Read/Write Setting) (16 modules)3E30 Field Shared Output 1 ID 0 to 65535 --- --- F205 "SO 1"3E36 Field Shared Output 1 Operate 0 to 4294967295 --- 1 F300 03E38 Field Shared Output 1 Unit Dest 1 0 to 8 --- 1 F256 0 (none)3E39 Field Shared Output 1 Channel Dest 1 0 to 15 --- 1 F001 13E3A Field Shared Output 1 Unit Dest 2 0 to 8 --- 1 F256 0 (none)3E3B Field Shared Output 1 Channel Dest 2 1 to 15 --- 1 F001 13E3C Field Shared Output 1 Events 0 to 1 --- 1 F102 1 (Enabled)3E3D ...Repeated for Field Shared Output 23E4A ...Repeated for Field Shared Output 33E57 ...Repeated for Field Shared Output 43E64 ...Repeated for Field Shared Output 53E71 ...Repeated for Field Shared Output 63E7E ...Repeated for Field Shared Output 73E8B ...Repeated for Field Shared Output 83E98 ...Repeated for Field Shared Output 93EA5 ...Repeated for Field Shared Output 103EB2 ...Repeated for Field Shared Output 113EBF ...Repeated for Field Shared Output 123ECC ...Repeated for Field Shared Output 133ED9 ...Repeated for Field Shared Output 143EE6 ...Repeated for Field Shared Output 153EF3 ...Repeated for Field Shared Output 16Field Unit RTDs (Read/Write Setting) (8 modules)3F00 Field Unit RTD 1Name 0 to 1 --- 1 F205 "RTD 1"3F06 Field Unit RTD 1 Origin 0 to 1 --- 1 F205 "RTD 1"3F07 Field Unit RTD 1 Type 0 to 2 --- 1 F259 0 (100 OhmNickel)3F08 ...Repeated for Field Unit RTD 23F10 ...Repeated for Field Unit RTD 33F18 ...Repeated for Field Unit RTD 43F20 ...Repeated for Field Unit RTD 53F28 ...Repeated for Field Unit RTD 63F30 ...Repeated for Field Unit RTD 73F38 ...Repeated for Field Unit RTD 8Field Unit Transducers (Read/Write Setting) (8 modules)3F40 Field Unit Transducer 1 Name 0 to 1 --- 1 F205 "TRD 1"3F46 Field Unit Transducer 1 Origin 0 to 24 --- 1 F53 0 (none)Table B–9: MODBUS MEMORY MAP (Sheet 15 of 60)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT