GE Multilin D30 Line Distance Protection System F-3APPENDIX F F.1 CHANGE NOTESF6- 6-7 Add Added new section for Real Time Clock synchronizing consisting of the menu of settings and thesetting descriptions6-10 6-10 Delete Deleted section 6.2.19 Ethernet Switch6- 6-10 Add Added new section 6.2.20 Remaining Connection Status7- 7-1 Add Added Security command to the Commands main menu7- 7-3 Add Added Reboot Relay command and description to the Relay Maintenance menu items7- 7- Add Added Security menu and submenu commands and descriptions to the Command menu7- 7- Add Added to Minor self-test error message **Bad PTP Signal**8- 8-4 Add Added new section for CyberSentry software option with overview and security menu subsectionsA- A- Add Added FlexAnalog item PTP–IRIG-B Delta to Table A-1: FlexAnalog Data ItemsB-8 B-8 Update Updated Modbus memory map table to include port 0 for Modbus slave address, TCP, DNP,HTTP, TFTP, MMS, and removed references to COM 1 RS485 portC-23 C-23 Update Updated tables in sections C.6.3 ACSI Services Conformance Statement and C.7.1 LogicalNodes TableTable F–4: MAJOR UPDATES FOR D30 MANUAL REVISION X2 (Sheet 1 of 2)PAGE(X1)PAGE(X2)CHANGE DESCRIPTIONAll All Update Changed safety symbols to new standardsTitle Title Update Changed part numbers. Removed copyright from title page. Updated ISO 9001 badge.CopyrightCopyrightUpdate Changed copyright to GE Multilin Inc. and updated part number1-3 1-3 Update Updated Figure 1-2 UR Concept Block Diagram to version A31-4 1-4 Update Updated Figure 1-3 UR-Series Scan Operation to version A31-16 1-16 Update Updated Figure 1-7 Relay Communication Options to version A22- 2- Update Updated ordering codes2- 2- Update Updated Latching Relay specifications in section 2.2.7 Outputs3- 3- Delete Removed references to 9L, 9M, 9P, and 9R modules in table and figure from section 3.2.9 CPUCommunication Ports3-4 3-4 Update Updated Figure 3-5 D30 Vertical Mounting and Dimensions to version A43-10 3-10 Update Updated Figure 3-12 Typical Wiring Diagram to version A73-17 3-17 Update Added surge to module 67 in Figure 3-17 Contact Input and Output Wiring3-19 3-19 Update Updated Figure 3-19 Dry and Wet Contact Input Connections to version A53-23 3-23 Update Changed 100Base-FL to 100Base-FX in Figure 3-24 CPU Module Communications Wiring3-24 3-24 Update Updated Figure 3-25 RS485 Serial Connection to version AA3-25 3-25 Update Updated Figure 3-26 IRIG-B Connection to version A63-25 3-25 Update Updated Figure 3-27 IRIG-B Repeater to version A23-26 3-26 Update Updated Figure 3-28 Direct Input and Output Single Channel Connection to version A23-26 3-26 Update Updated Figure 3-29 Direct Input and Output Dual Channel Connection to version A23-27 3-27 Update Updated Figure 3-30 Direct Input and Output Single/Dual Channel Combination Connection toversion A23-28 3-28 Update Updated Figure 3-31 LED and ELED Fiber Modules to version A33-29 3-29 Update Updated Figure 3-32 Laser Fiber Modules to version A53-29 3-29 Update Updated Figure 3-31 G.703 Interface Configuration to version A33-30 3-30 Update Updated Figure 3-33 Typical PIN Interconnection Between Two G.703 Interfaces to version A53-31 3-31 Update Updated Figure 3-35 G.703 Timing Selection Switch Setting to version A33-32 3-32 Update Updated dip switch figure 842752A1 in section 3.3.4d) G.703 Timing Modes to version A2Table F–3: MAJOR UPDATES FOR D30 MANUAL REVISION Y1 (Sheet 2 of 2)PAGE(X2)PAGE(Y1)CHANGE DESCRIPTION