GE Multilin D30 Line Distance Protection System E-5APPENDIX E E.1 DEVICE PROFILE DOCUMENTE20cont’d2 16-Bit Binary Counter 1 (read)7 (freeze)8 (freeze noack)9 (freeze clear)10 (frz. cl. noack)22 (assign class)00, 01 (start-stop)06 (no range, or all)07, 08 (limited quantity)17, 28 (index)129 (response) 00, 01 (start-stop)17, 28 (index)(see Note 2)5 32-Bit Binary Counter without Flag 1 (read)7 (freeze)8 (freeze noack)9 (freeze clear)10 (frz. cl. noack)22 (assign class)00, 01 (start-stop)06 (no range, or all)07, 08 (limited quantity)17, 28 (index)129 (response) 00, 01 (start-stop)17, 28 (index)(see Note 2)6 16-Bit Binary Counter without Flag 1 (read)7 (freeze)8 (freeze noack)9 (freeze clear)10 (frz. cl. noack)22 (assign class)00, 01 (start-stop)06 (no range, or all)07, 08 (limited quantity)17, 28 (index)129 (response) 00, 01 (start-stop)17, 28 (index)(see Note 2)21 0 Frozen Counter(Variation 0 is used to request defaultvariation)1 (read)22 (assign class)00, 01 (start-stop)06 (no range, or all)07, 08 (limited quantity)17, 28 (index)1 32-Bit Frozen Counter 1 (read)22 (assign class)00, 01 (start-stop)06 (no range, or all)07, 08 (limited quantity)17, 28 (index)129 (response) 00, 01 (start-stop)17, 28 (index)(see Note 2)2 16-Bit Frozen Counter 1 (read)22 (assign class)00, 01 (start-stop)06 (no range, or all)07, 08 (limited quantity)17, 28 (index)129 (response) 00, 01 (start-stop)17, 28 (index)(see Note 2)9 32-Bit Frozen Counter without Flag 1 (read)22 (assign class)00, 01 (start-stop)06 (no range, or all)07, 08 (limited quantity)17, 28 (index)129 (response) 00, 01 (start-stop)17, 28 (index)(see Note 2)10 16-Bit Frozen Counter without Flag 1 (read)22 (assign class)00, 01 (start-stop)06 (no range, or all)07, 08 (limited quantity)17, 28 (index)129 (response) 00, 01 (start-stop)17, 28 (index)(see Note 2)22 0 Counter Change Event (Variation 0 is usedto request default variation)1 (read) 06 (no range, or all)07, 08 (limited quantity)1 32-Bit Counter Change Event 1 (read) 06 (no range, or all)07, 08 (limited quantity)129 (response)130 (unsol. resp.)17, 28 (index)2 16-Bit Counter Change Event 1 (read) 06 (no range, or all)07, 08 (limited quantity)129 (response)130 (unsol. resp.)17, 28 (index)5 32-Bit Counter Change Event with Time 1 (read) 06 (no range, or all)07, 08 (limited quantity)129 (response)130 (unsol. resp.)17, 28 (index)6 16-Bit Counter Change Event with Time 1 (read) 06 (no range, or all)07, 08 (limited quantity)129 (response)130 (unsol. resp.)17, 28 (index)23 0 Frozen Counter Event (Variation 0 is usedto request default variation)1 (read) 06 (no range, or all)07, 08 (limited quantity)1 32-Bit Frozen Counter Event 1 (read) 06 (no range, or all)07, 08 (limited quantity)129 (response)130 (unsol. resp.)17, 28 (index)2 16-Bit Frozen Counter Event 1 (read) 06 (no range, or all)07, 08 (limited quantity)129 (response)130 (unsol. resp.)17, 28 (index)Table E–2: IMPLEMENTATION TABLE (Sheet 2 of 4)OBJECT REQUEST RESPONSEOBJECTNO. VARIATIONNO. DESCRIPTION FUNCTIONCODES (DEC) QUALIFIERCODES (HEX) FUNCTIONCODES (DEC) QUALIFIERCODES (HEX)Note 1: A default variation refers to the variation responded when variation 0 is requested and/or in class 0, 1, 2, or 3 scans. The default varia-tions for object types 1, 2, 20, 21, 22, 23, 30, and 32 are selected via relay settings. Refer to the Communications section in Chapter 5for details. This optimizes the class 0 poll data size.Note 2: For static (non-change-event) objects, qualifiers 17 or 28 are only responded when a request is sent with qualifiers 17 or 28, respec-tively. Otherwise, static object requests sent with qualifiers 00, 01, 06, 07, or 08, will be responded with qualifiers 00 or 01 (for change-event objects, qualifiers 17 or 28 are always responded.)Note 3: Cold restarts are implemented the same as warm restarts – the D30 is not restarted, but the DNP process is restarted.