Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- GETTING STARTED
- General cautions and warnings
- Communication board withdrawal/insertion
- Magnetic module terminals
- Inspection checklist
- Safety instructions
- General safety instructions
- Warning symbols
- Overview
- F650 signal type
- Protection
- EnerVista 650 Setup software
- Connecting EnerVista 650 Setup to the F650
- hardware
- Faceplate display
- Maintenance
- Repairs
- PRODUCT
- DESCRIPTION
- Other device functions
- Order codes
- CIO Modules
- Technical specifications
- Control
- Monitoring
- User-programmable
- Metering
- Real time clock
- Communications
- Optical
- Environmental
- Approvals
- External connections
- GEK-113000-AF F650 DIGITAL BAY CONTROLLER
- Viewing actual values
- Main screen
- Connect to the relay
- Computer Settings:
- File management menu
- Online mode
- EnerVista 650 Setup menu
- File menu
- New, Open, Save, Save as, and Close
- Configuration file converter
- Properties
- Compare to settings file
- Setting checksum calculation
- Product setup menu
- System setup menu
- Control elements menu
- Inputs/Outputs menu
- Quick settings menu
- Logic Configuration menu
- IEC 103 Configuration menu
- Actual values menu
- Operations menu
- Security menu
- View menu
- Human-machine interface (HMI)
- Display
- LED indicators
- Command push button
- Screen contrast
- Text menu hierarchy
- Snapshot events
- Fault report
- View settings menu
- Change Settings
- Date & time
- Commands
- Passwords
- Select main screen
- Graphic display
- Metering screen
- All events screen
- New events screen
- Alarms panel
- Input/output monitoring screen
- Web server
- Control events
- Alarms
- Oscillography
- Data logger
- SECURITY 4.1 Adding users
- Changing passwords
- Enabling security
- Logging into EnerVista 650 Setup
- Firmware upgrade versions below 7.00
- Communication parameters
- Bootware version upgrade
- Firmware version upgrade
- Summary of main steps
- Firmware upgrade(*)
- Firmware upgrade version 7.00 or above
- Order code upgrade process
- Summary of main firmware upgrade steps
- Visual inspection
- Out of service setting
- General considerations, power supply network
- Isolation tests
- Indicators
- Verification of measurement
- Active, reactive power, and COSJ metering
- Frequency
- Inputs and outputs
- Contact outputs
- Connections for testing protection elements
- Instantaneous overcurrent (50PH, 50PL, 50N, 50G, 50SG)
- Time overcurrent (51PH, 51PL, 51N, 51G, 46)
- Directional elements (67P, 67N, 67G, 67SG)
- G element
- Undervoltage elements (27P, 27X)
- Overvoltage elements (59P, 59X, 59NH, 59NL, 47)
- NH and 59NL elements
- Frequency elements (81O/81U)
- Recloser (79)
- Recloser status
- Thermal image element (49)
- Control & HMI
- Relay configuration
- Symptoms and recommended actions
- A.1 Operands - F650 - model FX - GX
- B.1 PRP and HSR Ethernet protocols
- B.1.1 PRP
- B.1.2 HSR
- B.2 RSTP (IEEE 802.1D-2004) and daisy chain
- B.2.3 Use in meshed networks
- B.3 Link loss alert (LLA)
- D.1 Factory default settings
- D.2 Factory default configuration
- E.1 GE Multilin warranty
|
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.2 HUMAN-MACHINE INTERFACE (HMI)GEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-55Setting passwd.Login: < 1000 >For entering the desired password, the user must press up-down key or rotate the shuttle key to the left (decrease) or tothe right (increase), and establish the desired number. Once entered, the selected password between brackets has beenentered, the relay shows the message "Processing passwd. Wait...". If the password is correct, the relay allows access tothe settings change or command execution. It is not necessary to enter the password every time a change is to beperformed. The relay requests the password again after 15 minutes of inactivity. This period of time is the same that takesthe relay to turn off the display backlighting.Logging out (Logout PWD)To disable access to settings and commands, the user must logout.Logout Pwd Settings or Logout Pwd Commands:For safety reasons, the relay automatically logs out the active user 15 minutes after the last keypad action.Changing the password (Change PWD commands)To set a password in the relay, both for settings and commands, the corresponding menu must be accessed inside thePassword menu:Change Pwd Settings or Change Pwd Commands:To change the password, the user must first log in with the existing password; if the relay has the default factorypassword, this would be 0000.The relay requests the existing password with the following message:(Setting or Command) passwd.Login: < 0000 >Once the existing password has been acknowledged, the new password must be entered:(Setting or Command) passwd.New passwd: < 1000 >Once the new password has been entered, the relay returns to the general Passwords menu.Password recovery (forgot password?)If the relay passwords need to be recovered, Forgot Password? must be accessed. This menu is the last option inside thetext Passwords menu.This menu shows two passwords, corresponding to the encrypted protection settings and commands passwords, asshown in the following example:Cod Settings: [35c0]Cod Commands: [35c0]In order to obtain the decoded password from the encrypted codes provided by the relay, it is necessary to contact GEMultilin and provide these encrypted codes. PreviousNext |