Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- GETTING STARTED
- General cautions and warnings
- Communication board withdrawal/insertion
- Magnetic module terminals
- Inspection checklist
- Safety instructions
- General safety instructions
- Warning symbols
- Overview
- F650 signal type
- Protection
- EnerVista 650 Setup software
- Connecting EnerVista 650 Setup to the F650
- hardware
- Faceplate display
- Maintenance
- Repairs
- PRODUCT
- DESCRIPTION
- Other device functions
- Order codes
- CIO Modules
- Technical specifications
- Control
- Monitoring
- User-programmable
- Metering
- Real time clock
- Communications
- Optical
- Environmental
- Approvals
- External connections
- GEK-113000-AF F650 DIGITAL BAY CONTROLLER
- Viewing actual values
- Main screen
- Connect to the relay
- Computer Settings:
- File management menu
- Online mode
- EnerVista 650 Setup menu
- File menu
- New, Open, Save, Save as, and Close
- Configuration file converter
- Properties
- Compare to settings file
- Setting checksum calculation
- Product setup menu
- System setup menu
- Control elements menu
- Inputs/Outputs menu
- Quick settings menu
- Logic Configuration menu
- IEC 103 Configuration menu
- Actual values menu
- Operations menu
- Security menu
- View menu
- Human-machine interface (HMI)
- Display
- LED indicators
- Command push button
- Screen contrast
- Text menu hierarchy
- Snapshot events
- Fault report
- View settings menu
- Change Settings
- Date & time
- Commands
- Passwords
- Select main screen
- Graphic display
- Metering screen
- All events screen
- New events screen
- Alarms panel
- Input/output monitoring screen
- Web server
- Control events
- Alarms
- Oscillography
- Data logger
- SECURITY 4.1 Adding users
- Changing passwords
- Enabling security
- Logging into EnerVista 650 Setup
- Firmware upgrade versions below 7.00
- Communication parameters
- Bootware version upgrade
- Firmware version upgrade
- Summary of main steps
- Firmware upgrade(*)
- Firmware upgrade version 7.00 or above
- Order code upgrade process
- Summary of main firmware upgrade steps
- Visual inspection
- Out of service setting
- General considerations, power supply network
- Isolation tests
- Indicators
- Verification of measurement
- Active, reactive power, and COSJ metering
- Frequency
- Inputs and outputs
- Contact outputs
- Connections for testing protection elements
- Instantaneous overcurrent (50PH, 50PL, 50N, 50G, 50SG)
- Time overcurrent (51PH, 51PL, 51N, 51G, 46)
- Directional elements (67P, 67N, 67G, 67SG)
- G element
- Undervoltage elements (27P, 27X)
- Overvoltage elements (59P, 59X, 59NH, 59NL, 47)
- NH and 59NL elements
- Frequency elements (81O/81U)
- Recloser (79)
- Recloser status
- Thermal image element (49)
- Control & HMI
- Relay configuration
- Symptoms and recommended actions
- A.1 Operands - F650 - model FX - GX
- B.1 PRP and HSR Ethernet protocols
- B.1.1 PRP
- B.1.2 HSR
- B.2 RSTP (IEEE 802.1D-2004) and daisy chain
- B.2.3 Use in meshed networks
- B.3 Link loss alert (LLA)
- D.1 Factory default settings
- D.2 Factory default configuration
- E.1 GE Multilin warranty
|
APPENDIX A: A.1 OPERANDS - F650 - MODEL FX - GXGEK-113000-AF F650 DIGITAL BAY CONTROLLER A-25OverfrequencyOVERFREQ1 BLOCK Overfrequency element block Group 1OVERFREQ1 PKP Overfrequency element pickup Group 1OVERFREQ1 OP Overfrequency element operation Group 1OVERFREQ2 BLOCK Overfrequency element block Group 2OVERFREQ2 PKP Overfrequency element pickup Group 2OVERFREQ2 OP Overfrequency element operation Group 2OVERFREQ3 BLOCK Overfrequency element block Group 3OVERFREQ3 PKP Overfrequency element pickup Group 3OVERFREQ3 OP Overfrequency element operation Group 3UnderfrequencyUNDERFREQ1 BLOCK Underfrequency element block Group 1UNDERFREQ1 PKP Underfrequency element pickup Group 1UNDERFREQ1 OP Underfrequency element operation Group 1UNDERFREQ2 BLOCK Underfrequency element block Group 2UNDERFREQ2 PKP Underfrequency element pickup Group 2UNDERFREQ2 OP Underfrequency element operation Group 2UNDERFREQ3 BLOCK Underfrequency element block Group 3UNDERFREQ3 PKP Underfrequency element pickup Group 3UNDERFREQ3 OP Underfrequency element operation Group 3Frequency rate of changeFREQ RATE1 BLOCK Frequency rate of change element block Group 1FREQ RATE1 PKP Frequency rate of change element pickup Group 1FREQ RATE1 OP Frequency rate of change element operation Group 1FREQ RATE2 BLOCK Frequency rate of change element block Group 2FREQ RATE2 PKP Frequency rate of change element pickup Group 2FREQ RATE2 OP Frequency rate of change element operation Group 2FREQ RATE3 BLOCK Frequency rate of change element block Group 3FREQ RATE3 PKP Frequency rate of change element pickup Group 3FREQ RATE3 OP Frequency rate of change element operation Group 3Broken ConductorBROKEN CONDUCT1 BLK Broken conductor block Group 1BROKEN CONDUCT1 PKP Broken conductor element Pickup Group 1BROKEN CONDUCT1 OP Broken conductor element operation Group 1BROKEN CONDUCT2 BLK Broken conductor block Group 2BROKEN CONDUCT2 PKP Broken conductor element Pickup Group 2BROKEN CONDUCT2 OP Broken conductor element operation Group 2BROKEN CONDUCT3 BLK Broken conductor block Group 3BROKEN CONDUCT3 PKP Broken conductor element Pickup Group 3BROKEN CONDUCT3 OP Broken conductor element operation Group 3OPERANDS - F650 - MODEL FX - GXInternal System Status PreviousNext |