Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- GETTING STARTED
- General cautions and warnings
- Communication board withdrawal/insertion
- Magnetic module terminals
- Inspection checklist
- Safety instructions
- General safety instructions
- Warning symbols
- Overview
- F650 signal type
- Protection
- EnerVista 650 Setup software
- Connecting EnerVista 650 Setup to the F650
- hardware
- Faceplate display
- Maintenance
- Repairs
- PRODUCT
- DESCRIPTION
- Other device functions
- Order codes
- CIO Modules
- Technical specifications
- Control
- Monitoring
- User-programmable
- Metering
- Real time clock
- Communications
- Optical
- Environmental
- Approvals
- External connections
- GEK-113000-AF F650 DIGITAL BAY CONTROLLER
- Viewing actual values
- Main screen
- Connect to the relay
- Computer Settings:
- File management menu
- Online mode
- EnerVista 650 Setup menu
- File menu
- New, Open, Save, Save as, and Close
- Configuration file converter
- Properties
- Compare to settings file
- Setting checksum calculation
- Product setup menu
- System setup menu
- Control elements menu
- Inputs/Outputs menu
- Quick settings menu
- Logic Configuration menu
- IEC 103 Configuration menu
- Actual values menu
- Operations menu
- Security menu
- View menu
- Human-machine interface (HMI)
- Display
- LED indicators
- Command push button
- Screen contrast
- Text menu hierarchy
- Snapshot events
- Fault report
- View settings menu
- Change Settings
- Date & time
- Commands
- Passwords
- Select main screen
- Graphic display
- Metering screen
- All events screen
- New events screen
- Alarms panel
- Input/output monitoring screen
- Web server
- Control events
- Alarms
- Oscillography
- Data logger
- SECURITY 4.1 Adding users
- Changing passwords
- Enabling security
- Logging into EnerVista 650 Setup
- Firmware upgrade versions below 7.00
- Communication parameters
- Bootware version upgrade
- Firmware version upgrade
- Summary of main steps
- Firmware upgrade(*)
- Firmware upgrade version 7.00 or above
- Order code upgrade process
- Summary of main firmware upgrade steps
- Visual inspection
- Out of service setting
- General considerations, power supply network
- Isolation tests
- Indicators
- Verification of measurement
- Active, reactive power, and COSJ metering
- Frequency
- Inputs and outputs
- Contact outputs
- Connections for testing protection elements
- Instantaneous overcurrent (50PH, 50PL, 50N, 50G, 50SG)
- Time overcurrent (51PH, 51PL, 51N, 51G, 46)
- Directional elements (67P, 67N, 67G, 67SG)
- G element
- Undervoltage elements (27P, 27X)
- Overvoltage elements (59P, 59X, 59NH, 59NL, 47)
- NH and 59NL elements
- Frequency elements (81O/81U)
- Recloser (79)
- Recloser status
- Thermal image element (49)
- Control & HMI
- Relay configuration
- Symptoms and recommended actions
- A.1 Operands - F650 - model FX - GX
- B.1 PRP and HSR Ethernet protocols
- B.1.1 PRP
- B.1.2 HSR
- B.2 RSTP (IEEE 802.1D-2004) and daisy chain
- B.2.3 Use in meshed networks
- B.3 Link loss alert (LLA)
- D.1 Factory default settings
- D.2 Factory default configuration
- E.1 GE Multilin warranty
|
APPENDIX A: A.1 OPERANDS - F650 - MODEL FX - GXGEK-113000-AF F650 DIGITAL BAY CONTROLLER A-15Phase TOC HighPH TOC1 HIGH A BLK Phase timed overcurrent element block Group 1 phase APH TOC1 HIGH B BLK Phase timed overcurrent element block Group 1 phase BPH TOC1 HIGH C BLK Phase timed overcurrent element block Group 1 phaseCPH TOC1 HIGH A PKP Phase timed overcurrent element pickup Group 1 phaseAPH TOC1 HIGH A OP Phase timed overcurrent element operation (trip) Group1 phase APH TOC1 HIGH B PKP Phase timed overcurrent element pickup Group 1 phaseBPH TOC1 HIGH B OP Phase timed overcurrent element operation (trip) Group1 phase BPH TOC1 HIGH C PKP Phase timed overcurrent element pickup Group 1 phaseCPH TOC1 HIGH C OP Phase timed overcurrent element operation (trip) Group1 phase CPH TOC1 HIGH PKP Phase timed overcurrent element pickup Group 1 anyphasePH TOC1 HIGH OP Phase timed overcurrent element operation (trip) Group1 any phasePH TOC2 HIGH A BLK Phase timed overcurrent element block Group 2 phase APH TOC2 HIGH B BLK Phase timed overcurrent element block Group 2 phase BPH TOC2 HIGH C BLK Phase timed overcurrent element block Group 2 phaseCPH TOC2 HIGH A PKP Phase timed overcurrent element pickup Group 2 phaseAPH TOC2 HIGH A OP Phase timed overcurrent element operation (trip) Group2 phase APH TOC2 HIGH B PKP Phase timed overcurrent element pickup Group 2 phaseBPH TOC2 HIGH B OP Phase timed overcurrent element operation (trip) Group2 phase BPH TOC2 HIGH C PKP Phase timed overcurrent element pickup Group 2 phaseCPH TOC2 HIGH C OP Phase timed overcurrent element operation (trip) Group2 phase CPH TOC2 HIGH PKP Phase timed overcurrent element pickup Group 2 anyphasePH TOC2 HIGH OP Phase timed overcurrent element operation (trip) Group2 any phasePH TOC3 HIGH A BLK Phase timed overcurrent element block Group 3 phase APH TOC3 HIGH B BLK Phase timed overcurrent element block Group 3 phase BPH TOC3 HIGH C BLK Phase timed overcurrent element block Group 3 phaseCOPERANDS - F650 - MODEL FX - GXInternal System Status PreviousNext |