Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- GETTING STARTED
- General cautions and warnings
- Communication board withdrawal/insertion
- Magnetic module terminals
- Inspection checklist
- Safety instructions
- General safety instructions
- Warning symbols
- Overview
- F650 signal type
- Protection
- EnerVista 650 Setup software
- Connecting EnerVista 650 Setup to the F650
- hardware
- Faceplate display
- Maintenance
- Repairs
- PRODUCT
- DESCRIPTION
- Other device functions
- Order codes
- CIO Modules
- Technical specifications
- Control
- Monitoring
- User-programmable
- Metering
- Real time clock
- Communications
- Optical
- Environmental
- Approvals
- External connections
- GEK-113000-AF F650 DIGITAL BAY CONTROLLER
- Viewing actual values
- Main screen
- Connect to the relay
- Computer Settings:
- File management menu
- Online mode
- EnerVista 650 Setup menu
- File menu
- New, Open, Save, Save as, and Close
- Configuration file converter
- Properties
- Compare to settings file
- Setting checksum calculation
- Product setup menu
- System setup menu
- Control elements menu
- Inputs/Outputs menu
- Quick settings menu
- Logic Configuration menu
- IEC 103 Configuration menu
- Actual values menu
- Operations menu
- Security menu
- View menu
- Human-machine interface (HMI)
- Display
- LED indicators
- Command push button
- Screen contrast
- Text menu hierarchy
- Snapshot events
- Fault report
- View settings menu
- Change Settings
- Date & time
- Commands
- Passwords
- Select main screen
- Graphic display
- Metering screen
- All events screen
- New events screen
- Alarms panel
- Input/output monitoring screen
- Web server
- Control events
- Alarms
- Oscillography
- Data logger
- SECURITY 4.1 Adding users
- Changing passwords
- Enabling security
- Logging into EnerVista 650 Setup
- Firmware upgrade versions below 7.00
- Communication parameters
- Bootware version upgrade
- Firmware version upgrade
- Summary of main steps
- Firmware upgrade(*)
- Firmware upgrade version 7.00 or above
- Order code upgrade process
- Summary of main firmware upgrade steps
- Visual inspection
- Out of service setting
- General considerations, power supply network
- Isolation tests
- Indicators
- Verification of measurement
- Active, reactive power, and COSJ metering
- Frequency
- Inputs and outputs
- Contact outputs
- Connections for testing protection elements
- Instantaneous overcurrent (50PH, 50PL, 50N, 50G, 50SG)
- Time overcurrent (51PH, 51PL, 51N, 51G, 46)
- Directional elements (67P, 67N, 67G, 67SG)
- G element
- Undervoltage elements (27P, 27X)
- Overvoltage elements (59P, 59X, 59NH, 59NL, 47)
- NH and 59NL elements
- Frequency elements (81O/81U)
- Recloser (79)
- Recloser status
- Thermal image element (49)
- Control & HMI
- Relay configuration
- Symptoms and recommended actions
- A.1 Operands - F650 - model FX - GX
- B.1 PRP and HSR Ethernet protocols
- B.1.1 PRP
- B.1.2 HSR
- B.2 RSTP (IEEE 802.1D-2004) and daisy chain
- B.2.3 Use in meshed networks
- B.3 Link loss alert (LLA)
- D.1 Factory default settings
- D.2 Factory default configuration
- E.1 GE Multilin warranty
|
APPENDIX D: D.1 FACTORY DEFAULT SETTINGSGEK-113000-AF F650 DIGITAL BAY CONTROLLER d-25Digital Counter 6 name DigCnt 6 Name NADigital counter 6 Preset DigCnt 6 Preset 0 1[-2147483648 :2147483647]Digital counter 6 Compare DigCnt 6 Compare 0 1[-2147483648 :2147483647]Function permission DigCnt 7 Function DISABLED NADigital Counter 7 name DigCnt 7 Name NADigital counter 7 Preset DigCnt 7 Preset 0 1[-2147483648 :2147483647]Digital counter 7 Compare DigCnt 7 Compare 0 1[-2147483648 :2147483647]Function permission DigCnt 8 Function DISABLED NADigital Counter 8 name DigCnt 8 Name NADigital counter 8 Preset DigCnt 8 Preset 0 1[-2147483648 :2147483647]Digital counter 8 Compare DigCnt 8 Compare 0 1[-2147483648 :2147483647]Snapshot Event Generation Snapshot Events ENABLED NA [ENABLED; DISABLED]SETPOINT > CONTROL ELEMENTS > COLD LOAD PICK UPSETTING DESCRIPTION NAME DEFAULT VALUE STEP RANGE USERVALUEFunction permsision Cold Load Function DISABLED NA [ENABLED; DISABLED]Cold Load Pickup Outage Time Cold Outage Time 20min [1 : 1000]Cold Load Pickup Blocking Time Cold Blocking Time 5 s [1 : 1000]Snapshot Event Generation Cold Load Events ENABLED NA [ENABLED; DISABLED]Setpoint > Inputs/Outputs > Contact I/O >Board F > Board G >board h>board jSetting Description Name Default Value Step Range UserValueI/O board type (available only for CIOmodules)I/O Board Type_X NONE N/A [NONE,16 INP + 8OUT,8 INP + 8OUT + SUPV32 INP16 INP + 8 ANA]Input activation voltage threshold Group A Voltage Threshold A_X 80 1 V [10 : 230]Input activation voltage threshold Group B Voltage Threshold B_X 80 1 V [10 : 230]Input activation voltage threshold Group C Voltage Threshold C_X 80 1 V [10 : 230]Input activation voltage threshold Group D Voltage Threshold D_X 80 1 V [10 : 230]Debounce time for Group A Debounce Time A_X 15 1 ms [1 : 50]Debounce time for Group B Debounce Time B_X 15 1 ms [1 : 50]Debounce time for Group C Debounce Time C_X 15 1 ms [1 : 50]Debounce time for Group D Debounce Time D_X 15 1 ms [1 : 50]Input type Input Type_X_CCY(CCY)POSITIVE N/A [POSITIVE-EDGE,NEGATIVE-EDGE,POSITIVE,NEGATIVE]Input signal time delay Delay InputTime_X_CCY (CCY)0 1 ms [0 : 60000]Output logic type Output Logic_X_0Z POSITIVE N/A [POSITIVE,NEGATIVE] PreviousNext |