Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- GETTING STARTED
- General cautions and warnings
- Communication board withdrawal/insertion
- Magnetic module terminals
- Inspection checklist
- Safety instructions
- General safety instructions
- Warning symbols
- Overview
- F650 signal type
- Protection
- EnerVista 650 Setup software
- Connecting EnerVista 650 Setup to the F650
- hardware
- Faceplate display
- Maintenance
- Repairs
- PRODUCT
- DESCRIPTION
- Other device functions
- Order codes
- CIO Modules
- Technical specifications
- Control
- Monitoring
- User-programmable
- Metering
- Real time clock
- Communications
- Optical
- Environmental
- Approvals
- External connections
- GEK-113000-AF F650 DIGITAL BAY CONTROLLER
- Viewing actual values
- Main screen
- Connect to the relay
- Computer Settings:
- File management menu
- Online mode
- EnerVista 650 Setup menu
- File menu
- New, Open, Save, Save as, and Close
- Configuration file converter
- Properties
- Compare to settings file
- Setting checksum calculation
- Product setup menu
- System setup menu
- Control elements menu
- Inputs/Outputs menu
- Quick settings menu
- Logic Configuration menu
- IEC 103 Configuration menu
- Actual values menu
- Operations menu
- Security menu
- View menu
- Human-machine interface (HMI)
- Display
- LED indicators
- Command push button
- Screen contrast
- Text menu hierarchy
- Snapshot events
- Fault report
- View settings menu
- Change Settings
- Date & time
- Commands
- Passwords
- Select main screen
- Graphic display
- Metering screen
- All events screen
- New events screen
- Alarms panel
- Input/output monitoring screen
- Web server
- Control events
- Alarms
- Oscillography
- Data logger
- SECURITY 4.1 Adding users
- Changing passwords
- Enabling security
- Logging into EnerVista 650 Setup
- Firmware upgrade versions below 7.00
- Communication parameters
- Bootware version upgrade
- Firmware version upgrade
- Summary of main steps
- Firmware upgrade(*)
- Firmware upgrade version 7.00 or above
- Order code upgrade process
- Summary of main firmware upgrade steps
- Visual inspection
- Out of service setting
- General considerations, power supply network
- Isolation tests
- Indicators
- Verification of measurement
- Active, reactive power, and COSJ metering
- Frequency
- Inputs and outputs
- Contact outputs
- Connections for testing protection elements
- Instantaneous overcurrent (50PH, 50PL, 50N, 50G, 50SG)
- Time overcurrent (51PH, 51PL, 51N, 51G, 46)
- Directional elements (67P, 67N, 67G, 67SG)
- G element
- Undervoltage elements (27P, 27X)
- Overvoltage elements (59P, 59X, 59NH, 59NL, 47)
- NH and 59NL elements
- Frequency elements (81O/81U)
- Recloser (79)
- Recloser status
- Thermal image element (49)
- Control & HMI
- Relay configuration
- Symptoms and recommended actions
- A.1 Operands - F650 - model FX - GX
- B.1 PRP and HSR Ethernet protocols
- B.1.1 PRP
- B.1.2 HSR
- B.2 RSTP (IEEE 802.1D-2004) and daisy chain
- B.2.3 Use in meshed networks
- B.3 Link loss alert (LLA)
- D.1 Factory default settings
- D.2 Factory default configuration
- E.1 GE Multilin warranty
|
D-14 F650 DIGITAL BAY CONTROLLER GEK-113000-AFD.1 FACTORY DEFAULT SETTINGS APPENDIX D:Input type Input PHASOR(DFT) N/A [PHASOR – RMS]Pickup level Pickup Level 30.00 0.01A [0.05 : 160.00]Trip time Trip Delay 0.00 0.01s [0.00 : 900.00]Reset time Reset Delay 0.00 0.01s [0.00 : 900.00]Snapshot event generation Snapshot Events ENABLED N/A [DISABLED – ENABLED]Setpoint > Protection Elements > Phase Current > Phase Directional >Phase Directional 1> Phase Directional 2 > Phase Directional 3Setting Description Name Default Value Step Range UserValueFunction permission Function DISABLED N/A [DISABLED – ENABLED]Maximum Torque Angle MTA 45 1Deg [-90 : +90]Operation Direction Direction FORWARD N/A [FORWARD – REVERSE]Block logic Block Logic PERMISSION N/A [BLOCK – PERMISSION]Polarization voltage threshold Pol V Threshold 40 1 V [0 : 300]Snapshot event generation Snapshot Events ENABLED N/A [DISABLED – ENABLED]Voltage Memory Voltage Memory 0,00 s 0,01s [0,00 : 3,00]Setpoint > Protection Elements > Phase Current > Thermal Model >Thermal Model 1 > Thermal Model 2 > Thermal Model 3Setting Description Name Default Value Step Range UserValueFunction permission Function DISABLED N/A [DISABLED – ENABLED]Heating constant Heat Time Constant 6.0 0.1min [3.0 : 600.0]Cooling constant Cool Time Constant 2.000.01timesHeatTimeCt.[1.00 : 6.00]Pickup level Pickup Level 1.00 0.01A [0.05 : 160.00]Alarm level Alarm Level 80.0 0.10% [1.0 : 110.0]Snapshot event generation Snapshot Events ENABLED N/A [DISABLED – ENABLED]Setpoint > Protection Elements > Neutral Current > Neutral TOCNeutral TOC 1> Neutral TOC 2 > Neutral TOC 3Setting Description Name Default Value Step Range UserValueFunction permission Function DISABLED N/A [DISABLED – ENABLED]Pickup level Pickup Level 1.00 0.01A [0.05 : 160.00]Curve shape Curve IEEE Ext Inv N/A [See list of curves]Time Dial TD Multiplier 1.00 0.01s [0.00 : 900.00]Reset type Reset INSTANTANEOUS N/A [INSTANTANEOUS – LINEAR]Snapshot Event generation Snapshot Events ENABLED N/A [DISABLED – ENABLED] PreviousNext |