Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- GETTING STARTED
- General cautions and warnings
- Communication board withdrawal/insertion
- Magnetic module terminals
- Inspection checklist
- Safety instructions
- General safety instructions
- Warning symbols
- Overview
- F650 signal type
- Protection
- EnerVista 650 Setup software
- Connecting EnerVista 650 Setup to the F650
- hardware
- Faceplate display
- Maintenance
- Repairs
- PRODUCT
- DESCRIPTION
- Other device functions
- Order codes
- CIO Modules
- Technical specifications
- Control
- Monitoring
- User-programmable
- Metering
- Real time clock
- Communications
- Optical
- Environmental
- Approvals
- External connections
- GEK-113000-AF F650 DIGITAL BAY CONTROLLER
- Viewing actual values
- Main screen
- Connect to the relay
- Computer Settings:
- File management menu
- Online mode
- EnerVista 650 Setup menu
- File menu
- New, Open, Save, Save as, and Close
- Configuration file converter
- Properties
- Compare to settings file
- Setting checksum calculation
- Product setup menu
- System setup menu
- Control elements menu
- Inputs/Outputs menu
- Quick settings menu
- Logic Configuration menu
- IEC 103 Configuration menu
- Actual values menu
- Operations menu
- Security menu
- View menu
- Human-machine interface (HMI)
- Display
- LED indicators
- Command push button
- Screen contrast
- Text menu hierarchy
- Snapshot events
- Fault report
- View settings menu
- Change Settings
- Date & time
- Commands
- Passwords
- Select main screen
- Graphic display
- Metering screen
- All events screen
- New events screen
- Alarms panel
- Input/output monitoring screen
- Web server
- Control events
- Alarms
- Oscillography
- Data logger
- SECURITY 4.1 Adding users
- Changing passwords
- Enabling security
- Logging into EnerVista 650 Setup
- Firmware upgrade versions below 7.00
- Communication parameters
- Bootware version upgrade
- Firmware version upgrade
- Summary of main steps
- Firmware upgrade(*)
- Firmware upgrade version 7.00 or above
- Order code upgrade process
- Summary of main firmware upgrade steps
- Visual inspection
- Out of service setting
- General considerations, power supply network
- Isolation tests
- Indicators
- Verification of measurement
- Active, reactive power, and COSJ metering
- Frequency
- Inputs and outputs
- Contact outputs
- Connections for testing protection elements
- Instantaneous overcurrent (50PH, 50PL, 50N, 50G, 50SG)
- Time overcurrent (51PH, 51PL, 51N, 51G, 46)
- Directional elements (67P, 67N, 67G, 67SG)
- G element
- Undervoltage elements (27P, 27X)
- Overvoltage elements (59P, 59X, 59NH, 59NL, 47)
- NH and 59NL elements
- Frequency elements (81O/81U)
- Recloser (79)
- Recloser status
- Thermal image element (49)
- Control & HMI
- Relay configuration
- Symptoms and recommended actions
- A.1 Operands - F650 - model FX - GX
- B.1 PRP and HSR Ethernet protocols
- B.1.1 PRP
- B.1.2 HSR
- B.2 RSTP (IEEE 802.1D-2004) and daisy chain
- B.2.3 Use in meshed networks
- B.3 Link loss alert (LLA)
- D.1 Factory default settings
- D.2 Factory default configuration
- E.1 GE Multilin warranty
|
2-8 F650 DIGITAL BAY CONTROLLER GEK-113000-AF2.5 TECHNICAL SPECIFICATIONS CHAPTER 2: PRODUCT DESCRIPTION2.5 Technical specificationsTECHNICAL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE2.5.1 ProtectionPhase and Ground protection functions use currents measured through CT inputs for performing internal calculations,while the Neutral protection functions use the current calculated from three phase currents.The sensitive ground protection functions are usually used for applications where the neutral is completely isolated. Thesefunctions use current measured though the sensitive ground current input. This CT has a sensitivity 10 time higher thanstandard CT inputs (Connected to 1A and 5A CT) and its current withstand is lower.PHASE TIME OVERCURRENT (51PH/51PL)Current Input: .............................................................................phasor (without harmonics) or RMSRated Current:............................................................................for connection to 1 or 5 A CTsPickup Level: ...............................................................................0.05 to 160.00 A in steps of 0.01 ADropout Level:............................................................................97% to 98% of the pickup levelLevel Accuracy: .........................................................................values at nominal frequency:±0.5% of the reading ± 10 mA from 0.05 to 10.00 A±1.5% of the reading for higher valuesCurve Shape: ..............................................................................IEEE extremely/very/moderately inverseIEC A/B/C/long-time inverse/short time inverse curveIAC extremely/very/moderately inverseANSI extremely/very/normally/moderately inverseI2tDefinite timeRectifier curveFlexCurveTM A/B/C/D user curveCurve Multiplier (Time Dial):.................................................0.00 to 900.00 s in steps of 0.01 sReset Type: ..................................................................................instantaneous or time delayed, according to IEEETiming Accuracy: .....................................................................Operate at > 1.03 times the pickup ±3% of operate time or 50 ms(whichever is greater)Voltage Restraint: .....................................................................selectable by settingSaturation Level: .......................................................................48 times the pickup levelSnapshot Events: ......................................................................selectable by setting PreviousNext |