- GETTING STARTED
- General cautions and warnings
- Communication board withdrawal/insertion
- Magnetic module terminals
- Inspection checklist
- Safety instructions
- General safety instructions
- Warning symbols
- Overview
- F650 signal type
- Protection
- EnerVista 650 Setup software
- Connecting EnerVista 650 Setup to the F650
- hardware
- Faceplate display
- Maintenance
- Repairs
- PRODUCT
- DESCRIPTION
- Other device functions
- Order codes
- CIO Modules
- Technical specifications
- Control
- Monitoring
- User-programmable
- Metering
- Real time clock
- Communications
- Optical
- Environmental
- Approvals
- External connections
- GEK-113000-AF F650 DIGITAL BAY CONTROLLER
- Viewing actual values
- Main screen
- Connect to the relay
- Computer Settings:
- File management menu
- Online mode
- EnerVista 650 Setup menu
- File menu
- New, Open, Save, Save as, and Close
- Configuration file converter
- Properties
- Compare to settings file
- Setting checksum calculation
- Product setup menu
- System setup menu
- Control elements menu
- Inputs/Outputs menu
- Quick settings menu
- Logic Configuration menu
- IEC 103 Configuration menu
- Actual values menu
- Operations menu
- Security menu
- View menu
- Human-machine interface (HMI)
- Display
- LED indicators
- Command push button
- Screen contrast
- Text menu hierarchy
- Snapshot events
- Fault report
- View settings menu
- Change Settings
- Date & time
- Commands
- Passwords
- Select main screen
- Graphic display
- Metering screen
- All events screen
- New events screen
- Alarms panel
- Input/output monitoring screen
- Web server
- Control events
- Alarms
- Oscillography
- Data logger
- SECURITY 4.1 Adding users
- Changing passwords
- Enabling security
- Logging into EnerVista 650 Setup
- Firmware upgrade versions below 7.00
- Communication parameters
- Bootware version upgrade
- Firmware version upgrade
- Summary of main steps
- Firmware upgrade(*)
- Firmware upgrade version 7.00 or above
- Order code upgrade process
- Summary of main firmware upgrade steps
- Visual inspection
- Out of service setting
- General considerations, power supply network
- Isolation tests
- Indicators
- Verification of measurement
- Active, reactive power, and COSJ metering
- Frequency
- Inputs and outputs
- Contact outputs
- Connections for testing protection elements
- Instantaneous overcurrent (50PH, 50PL, 50N, 50G, 50SG)
- Time overcurrent (51PH, 51PL, 51N, 51G, 46)
- Directional elements (67P, 67N, 67G, 67SG)
- G element
- Undervoltage elements (27P, 27X)
- Overvoltage elements (59P, 59X, 59NH, 59NL, 47)
- NH and 59NL elements
- Frequency elements (81O/81U)
- Recloser (79)
- Recloser status
- Thermal image element (49)
- Control & HMI
- Relay configuration
- Symptoms and recommended actions
- A.1 Operands - F650 - model FX - GX
- B.1 PRP and HSR Ethernet protocols
- B.1.1 PRP
- B.1.2 HSR
- B.2 RSTP (IEEE 802.1D-2004) and daisy chain
- B.2.3 Use in meshed networks
- B.3 Link loss alert (LLA)
- D.1 Factory default settings
- D.2 Factory default configuration
- E.1 GE Multilin warranty
|
CHAPTER 3: INTERFACES, SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWAREGEK-113000-AF F650 DIGITAL BAY CONTROLLER 3-313.1.8.4 Inputs/Outputs menuThe Inputs/Outputs menu includes all the inputs and outputs signals available in the device. Contact and virtual type.(*) indicates online only, (**) indicates offline only3.1.8.5 Records menuThe Records menu is only available in online mode and includes the possibility to retrieve all the records available in thedevice. By serial or Ethernet.(*) indicates online only, (**) indicates offline onlyinputs/outputsContact Inputs Status of digital inputs in the Relay for each board according to the relay model.Contact Output Status Status of digital outputs in the Relay for each board according to the relay model.Contact OutputsOperatesStatus (activated or not) of the variables used to operate a contact output. To configurethese signals go to Setpoint > Relay Configuration > Outputs menu.Contact OutputsResetsStatus (activated or not) of the variables used to reset a contact output. To configure thesesignals go to Setpoint > Relay Configuration > Outputs menu. This output resetCommand is only effective if latch is selected for Output Type setting on the I/O board,thus the contact output has been configured to emulate function 86 (latching relay).IO Board Status Status of I/O boards. This status provides if the hardware it is OK (boards matching relaymodel, correctly inserted in their tracks, in good state and communicating through theinternal CAN bus).Virtual Inputs Status of Virtual inputs latched (32) and self-reset (32).Virtual Outputs Status of virtual outputs (configured in PLC Editor). Up to 512.Remote Outputs States of remote outputs for IEC61850 models.Remote Inputs Status of remote device and remote inputs for IEC61850 models.Analog Inputs (*) Measurements coming from analog inputs (DCMA)Virtual Output Latched Status of Virtual Output Latched (configured in PLC Editor). Up to 16.Virtual outputAnalogueStatus of Virtual OutputAnalogues configured in PLC Editor). Up to 49 float values and 49integer values can be used.Records (*)Event recorder (*) Retrieval and visualization of snapshot event (all and new), control events and alarm panel.By serial or Ethernet (ModBus RTU or TCP/IP)Waveform capture (*) Retrieval of oscillography files, by Ethernet.Fault Report (*) Retrieval and visualization of fault report files, by Ethernet.Data logger (*) Retrieval and visualization of data logger files. Only by Ethernet. PreviousNext |