GE Multilin G60 Generator Management Relay B-11APPENDIX B B.4 MEMORY MAPPINGBData Logger Actuals (Read Only)1618 Data logger channel count 0 to 16 channel 1 F001 01619 Time of oldest available samples 0 to 4294967295 seconds 1 F050 0161B Time of newest available samples 0 to 4294967295 seconds 1 F050 0161D Data logger duration 0 to 999.9 days 0.1 F001 0Stator Differential Actuals (Read Only)1660 Generator Differential Iad 0 to 999999.999 A 0.001 F060 01662 Generator Restraint Iar 0 to 999999.999 A 0.001 F060 01664 Generator Differential Ibd 0 to 999999.999 A 0.001 F060 01666 Generator Restraint Ibr 0 to 999999.999 A 0.001 F060 01668 Generator Differential Icd 0 to 999999.999 A 0.001 F060 0166A Generator Restraint Icr 0 to 999999.999 A 0.001 F060 0Stator Ground Actuals (Read Only)1670 Stator Ground Vn 3rd 0 to 999999.999 V 0.001 F060 01672 Stator Ground Vn V0 3rd 0 to 999999.999 V 0.001 F060 0Sensitive Directional Power Actuals (Read Only) (2 modules)1680 Sensitive Directional Power 1 Power -2147483647 to 2147483647 W 1 F060 01682 Sensitive Directional Power 2 Power -2147483647 to 2147483647 W 1 F060 0Restricted Ground Fault Currents (Read Only) (6 modules)16A0 Differential Ground Current Magnitude 0 to 999999.999 A 0.001 F060 016A2 Restricted Ground Current Magnitude 0 to 999999.999 A 0.001 F060 016A4 ...Repeated for Restricted Ground Fault 216A8 ...Repeated for Restricted Ground Fault 316AC ...Repeated for Restricted Ground Fault 416B0 ...Repeated for Restricted Ground Fault 516B4 ...Repeated for Restricted Ground Fault 6Frequency Rate of Change Actuals (Read Only) (4 modules)16E0 Frequency Rate of Change 1 -327.67 to 327.67 Hz/s 0.01 F002 016E1 Reserved (3 items) 0 to 65535 --- 1 F001 016E4 ...Repeated for Frequency Rate of Change 216E8 ...Repeated for Frequency Rate of Change 316EC ...Repeated for Frequency Rate of Change 4Source Current (Read Only) (6 modules)1800 Source 1 Phase A Current RMS 0 to 999999.999 A 0.001 F060 01802 Source 1 Phase B Current RMS 0 to 999999.999 A 0.001 F060 01804 Source 1 Phase C Current RMS 0 to 999999.999 A 0.001 F060 01806 Source 1 Neutral Current RMS 0 to 999999.999 A 0.001 F060 01808 Source 1 Phase A Current Magnitude 0 to 999999.999 A 0.001 F060 0180A Source 1 Phase A Current Angle -359.9 to 0 degrees 0.1 F002 0180B Source 1 Phase B Current Magnitude 0 to 999999.999 A 0.001 F060 0180D Source 1 Phase B Current Angle -359.9 to 0 degrees 0.1 F002 0180E Source 1 Phase C Current Magnitude 0 to 999999.999 A 0.001 F060 01810 Source 1 Phase C Current Angle -359.9 to 0 degrees 0.1 F002 01811 Source 1 Neutral Current Magnitude 0 to 999999.999 A 0.001 F060 01813 Source 1 Neutral Current Angle -359.9 to 0 degrees 0.1 F002 01814 Source 1 Ground Current RMS 0 to 999999.999 A 0.001 F060 01816 Source 1 Ground Current Magnitude 0 to 999999.999 A 0.001 F060 01818 Source 1 Ground Current Angle -359.9 to 0 degrees 0.1 F002 01819 Source 1 Zero Sequence Current Magnitude 0 to 999999.999 A 0.001 F060 0181B Source 1 Zero Sequence Current Angle -359.9 to 0 degrees 0.1 F002 0181C Source 1 Positive Sequence Current Magnitude 0 to 999999.999 A 0.001 F060 0181E Source 1 Positive Sequence Current Angle -359.9 to 0 degrees 0.1 F002 0181F Source 1 Negative Sequence Current Magnitude 0 to 999999.999 A 0.001 F060 01821 Source 1 Negative Sequence Current Angle -359.9 to 0 degrees 0.1 F002 0Table B–9: MODBUS MEMORY MAP (Sheet 4 of 47)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT