GE Multilin G60 Generator Management Relay B-51APPENDIX B B.4 MEMORY MAPPINGBCA28 ...Repeated for Direct Output 13CA2A ...Repeated for Direct Output 14CA2C ...Repeated for Direct Output 15CA2E ...Repeated for Direct Output 16CA30 ...Repeated for Direct Output 17CA32 ...Repeated for Direct Output 18CA34 ...Repeated for Direct Output 19CA36 ...Repeated for Direct Output 20CA38 ...Repeated for Direct Output 21CA3A ...Repeated for Direct Output 22CA3C ...Repeated for Direct Output 23CA3E ...Repeated for Direct Output 24CA40 ...Repeated for Direct Output 25CA42 ...Repeated for Direct Output 26CA44 ...Repeated for Direct Output 27CA46 ...Repeated for Direct Output 28CA48 ...Repeated for Direct Output 29CA4A ...Repeated for Direct Output 30CA4C ...Repeated for Direct Output 31CA4E ...Repeated for Direct Output 32Direct Input/Output Alarms (Read/Write Setting)CAD0 Direct Input/Output Channel 1 CRC Alarm Function 0 to 1 --- 1 F102 0 (Disabled)CAD1 Direct I/O Channel 1 CRC Alarm Message Count 100 to 10000 --- 1 F001 600CAD2 Direct Input/Output Channel 1 CRC Alarm Threshold 1 to 1000 --- 1 F001 10CAD3 Direct Input/Output Channel 1 CRC Alarm Events 0 to 1 --- 1 F102 0 (Disabled)CAD4 Reserved (4 items) 1 to 1000 --- 1 F001 10CAD8 Direct Input/Output Channel 2 CRC Alarm Function 0 to 1 --- 1 F102 0 (Disabled)CAD9 Direct I/O Channel 2 CRC Alarm Message Count 100 to 10000 --- 1 F001 600CADA Direct Input/Output Channel 2 CRC Alarm Threshold 1 to 1000 --- 1 F001 10CADB Direct Input/Output Channel 2 CRC Alarm Events 0 to 1 --- 1 F102 0 (Disabled)CADC Reserved (4 items) 1 to 1000 --- 1 F001 10CAE0 Direct I/O Ch 1 Unreturned Messages Alarm Function 0 to 1 --- 1 F102 0 (Disabled)CAE1 Direct I/O Ch 1 Unreturned Messages Alarm Msg Count 100 to 10000 --- 1 F001 600CAE2 Direct I/O Ch 1 Unreturned Messages Alarm Threshold 1 to 1000 --- 1 F001 10CAE3 Direct I/O Ch 1 Unreturned Messages Alarm Events 0 to 1 --- 1 F102 0 (Disabled)CAE4 Reserved (4 items) 1 to 1000 --- 1 F001 10CAE8 Direct IO Ch 2 Unreturned Messages Alarm Function 0 to 1 --- 1 F102 0 (Disabled)CAE9 Direct I/O Ch 2 Unreturned Messages Alarm Msg Count 100 to 10000 --- 1 F001 600CAEA Direct I/O Ch 2 Unreturned Messages Alarm Threshold 1 to 1000 --- 1 F001 10CAEB Direct I/O Channel 2 Unreturned Messages Alarm Events 0 to 1 --- 1 F102 0 (Disabled)CAEC Reserved (4 items) 1 to 1000 --- 1 F001 10Remote Devices (Read/Write Setting) (16 modules)CB00 Remote Device 1 GSSE/GOOSE Application ID --- --- --- F209 “Remote Device 1“CB21 Remote Device 1 GOOSE Ethernet APPID 0 to 16383 --- 1 F001 0CB22 Remote Device 1 GOOSE Dataset 0 to 8 --- 1 F184 0 (Fixed)CB23 ...Repeated for Device 2CB46 ...Repeated for Device 3CB69 ...Repeated for Device 4CB8C ...Repeated for Device 5CBAF ...Repeated for Device 6CBD2 ...Repeated for Device 7CBF5 ...Repeated for Device 8CC18 ...Repeated for Device 9CC3B ...Repeated for Device 10Table B–9: MODBUS MEMORY MAP (Sheet 44 of 47)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT