9-6 M60 MOTOR PROTECTION SYSTEM – INSTRUCTION MANUALREPLACE MODULE CHAPTER 9: MAINTENANCE94. Click the OK button to save the change.9.5 Replace moduleThis section outlines how to replace a module.The relay, being modular in design, allows for the withdrawal and insertion of modules. Replace modules only with likemodules in their original factory configured slots.To replace a module:1. Open the enhanced faceplate to the left once the thumb screw has been removed. This allows for easy access of themodules for withdrawal. The new wide-angle hinge assembly in the enhanced front panel opens completely andallows easy access to all modules in the M60.Figure 9-4: Modules inside relay with front cover open (enhanced faceplate)The standard faceplate can be opened to the left once the black plastic sliding latch on the right side has been pushedup, as shown below.WARNING Withdraw or insert a module only when control power has been removed from the unit, and besure to insert only the correct module type into a slot, else personal injury, damage to the unitor connected equipment, or undesired operation can result.NOTICE To avoid damage to the equipment, use proper electrostatic discharge protection (for example, astatic strap) when coming in contact with modules while the relay is energized.842812A1.CDR