Chapter 14. Diagnostics290 PACSystems* RXi Distributed IO Controller User Manual GFK-2816FGroup/CategoryType/Error CodeDescription Cause Recommended Correction28-37-0-0 Unexpected PROFINETAlarm received.The PNC has received aPROFINET alarm that isunexpected. Possible causes couldinclude a malformed PROFINETAlarm packet or an Alarm for aPROFINET sub-module that is notconfigured.Consult Device manufacturerdocumentation.Note: Alarm details areprovided in the Fault Extra Data28-38-0-0 Manufacturer specificDiagnosis AppearsPROFINET Alarm received.A PROFINET Alarm has beenreceived indicating that amanufacturer specific diagnosticcondition has been detected on thePROFINET device.Consult Device manufacturerdocumentation.Note: Alarm details areprovided in the Fault Extra Data28-39-0-0 Manufacturer specificDiagnosis DisappearsPROFINET Alarm received.A PROFINET Alarm has beenreceived indicating that amanufacturer specific diagnosticcondition has been resolved on thePROFINET device.None.Note: Alarm details areprovided in the Fault Extra Data28-40-x-018 Channel Diagnosis AppearsPROFINET Alarm received.A PROFINET Alarm has beenreceived indicating that a Channel-level diagnostic condition hasoccurred on the PROFINETdevice.Consult Device manufacturerdocumentation.Note: Alarm details areprovided in the Fault Extra Data.28-41-x-018 Channel DiagnosisDisappears PROFINET Alarmreceived.A PROFINET Alarm has beenreceived indicating that a Channel-level diagnostic condition has beenresolved on the PROFINET device.None.Note: Alarm details areprovided in the Fault Extra Data28-42-x-y18 Channel Diagnosis AppearsPROFINET Alarm received(Alarm contains ExtendedChannel data).A PROFINET Alarm has beenreceived indicating that a Channel-level diagnostic condition hasoccurred on the PROFINETdevice.Consult Device manufacturerdocumentation.Note: Alarm details areprovided in the Fault Extra Data.For complex analog modules,the reference address displayedin the fault identifies faults in allchannels using the discretestatus data of the module’s firstchannel. If the fault is onchannel 1, the referenceaddress is bit 1 of the channel 1status data; if the fault is onchannel 2, the referenceaddress is bit 2 of the channel 1status data, etc.28-43-x-y18 Channel DiagnosisDisappears PROFINET Alarmreceived (Alarm containsExtended Channel data).A PROFINET Alarm has beenreceived indicating that a Channel-level diagnostic condition has beenresolved on the PROFINET device.None.Note: Alarm details areprovided in the Fault Extra Data.28-44-x-y18 Channel Diagnosis AppearsPROFINET Alarm received(Alarm contains QualifiedChannel data).A PROFINET Alarm has beenreceived indicating that a Channel-level diagnostic condition hasoccurred on the PROFINETdevice.Consult Device manufacturerdocumentation.Note: Alarm details areprovided in the Fault Extra Data.28-45-x-y18 Channel DiagnosisDisappears PROFINET Alarmreceived (Alarm containsQualified Channel data).A PROFINET Alarm has beenreceived indicating that a Channel-level diagnostic condition has beenresolved on the PROFINET device.None.Note: Alarm details areprovided in the Fault Extra Data. |
Related manuals for GE ICRXICTL000
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine