Features and Specifications 9-11February 2005Sample SystemSpecifications for SS880A standard sample system, comprisingan inlet needle valve, a built-in coalescing filter and sample cellwith bypass needle valve and venting tube, a pressure gage(various ranges), and an outlet needle valve with venting tube.Wetted Parts316 SSOperating PressureConfigurations available for 300, 500, 1,000, 2,000 or 3,000 psig(21, 35, 69, 207, or 345 bar), dependent on pressure gaugeMaximum Pressure Rating• Standard: 3,000 psig (207 bar)• Optional: 5,000 psig (345 bar)Other Options• Inlet pressure regulator, 0 to 500 psig (1 to 345 bar) outlet• Armored flowmeter, 1.3 to 13 SCFH• 10-ft (3-m), flexible, PTFE-lined, braided-stainless steel hosewith 1/8-in. tube connections. Not recommended for dew pointtemperatures below -103°F (-75°C).Optional Accessories• Infrared adapter connects to serial port of desktop or laptopPCs to add infrared capability• Portable, infrared, thermal printer with rechargeable batteryand 120 to 240-VAC battery charger. Printer dimensions: 6.3 ×6.5 × 2.3 in. (160 × 164 × 59 mm). Weight: 13 oz (370 g). Printwidth: 4 in. (104 mm).• PC Interface Software - PanaView™ Graphical User Interface.