MaintenanceDescriptionThe SL1100 system has several utilities to assist in troubleshooting and diagnosing problems bothduring and after installation.Side Tone Auto SetupPer each analog trunk (or all analog trunks) the most suitable Codec Filter setting for PRG 81-07 canbe automatically adjusted using PRG 90-68-01 and 02.During the trunk measurement process, the following LCD indications are provided.• During measurement: Measurement (x/5)x= number of measurements• Measure complete: Complete• Error condition: Error• Trunk busy: BusyAfter successful measurement, the option to copy the same settings to all analog trunks is shown.Side Tone Auto Setup available when the system is in an idle condition.Remote maintenance using PCProPCPro can remotely access the SL1100 for maintenance and diagnostics. Within PCPro, the debugterminal can be accessed to monitor the systems activity and logging. PCPro also has built-in reportsthat can display alarm data. If need be, an option in PCPro allows the technician to reset or initializethe system remotely. If the technician determines the problem is isolated to a specific slot, PCPro canreset only the slot in question.Quick System Check-upYou can check the System Information, VoIPDB Information and IP Address by doing a simpleoperation. Here are the information you can get from the operation mode: (For future information referto Navigation Key on page 1-532)Table 1-50 Quick System Check-upSetting Name DescriptionOperation Mode15-02-60:0(Standard)15-02-60:1 (Navi-gation)15-02-60:2 (SoftKey)System Informa-tionShows the following:• Version Information• MAC Address• Hardware KeyEnter Key + 3 Enter Key + 820 +Enter KeyMenu + 93 + EneterKeyVoIPDB Informa-tionShows the following:• Type of VoIP Hardware• Number of VoIP Channels (TopRight)• MAC Address• Active/ReservedEnter Key + 4 Enter Key + 830 +Enter KeyMenu + 94 + EnterKeyIP Address In-formationShows the following:• System (CPU) IP Address• VoIPDB IP AddressEnter Key + 6 Enter Key + 840 +Enter KeyMenu + 96 + EnterKeyISSUE 2.0 SL1100Features and Specifications Manual 1-491M