28Alarm ReportsDescriptionThe UNIVERGE SV9100 system logs various errors and reports information about the operation thatcan be used to determine the cause of a problem. The system can indicate several errors on themultiline telephone display, output to a USB stick on the GCD-CP10, or be downloaded in PCPro. Thereport data also can be sent via email.Alarm ReportThe Alarm Reports indicate:System start-up/upgrade date and timeBlade communication error with date and time and the restoration date and timeDate and time a blade was removed from the systemDate and time an extension was disconnected from the systemDate and time of any system data changeSample Alarm Report<< Alarm Report 05/16/2006 14:30 PAGE 001LVL NO STAT DATE TIME ITEM UNIT SLT PRT PARAMETERMIN 0002 REC 05/16/06 14:21 PKG Installation PRT 02 00MAJ 0010 ERR 05/16/06 14:21 ISDN Link PRT 02 12MAJ 0010 REC 05/16/06 14:21 ISDN Link PRT 02 12MIN 0002 ERR 05/16/06 14:33 PKG Installation PRT 02 00MIN 0002 ERR 05/16/06 14:33 PKG Installation ESI 05 00MIN 0002 ERR 05/16/06 14:33 PKG Installation SLIB 07 00MAJ 0050 WAR 05/16/06 14:33 System Start Up none 00 00MIN 0002 REC 05/16/06 14:33 PKG Installation PRT 02 00MAJ 0014 ERR 05/16/06 14:33 NTCPU-LAN Link none 00 00MAJ 0014 REC 05/16/06 14:35 NTCPU-LAN Link none 00 00MIN 0002 ERR 05/16/06 14:36 PKG Installation CTP 08 00