ENW415-1935 / A / 05.07.19 41finishingAir ShutterOpeningLeverFlame must envelopupper3/8" to 1/2"(12.7mm - 9.5mm) ofFlame sensor3/8” - 1/2”(9.5mm - 12.7mm)It’s important to periodically perform a visual check ofthe pilot and burner flames. Compare them to theillustration provided. If any flames appear abnormal,call a service person.Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas fl ow.Check Pressure Readings:Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubingover the test point. Gauge should read as described on the chartbelow. Check pressure with main burner operating on “HI”.Outlet pressure can be checked the same as above using screw(B). Gauge should read as described on the chart below. Checkpressure with main burner operating on “HI”.After taking pressure readings, be sure to turn screwsclockwise firmly to reseal. Do not overtorque.Leak test with a soap and water solution.Prior to pilot adjustment, ensure that the pilot assembly has not been painted. If overspray or painting ofthe pilot assembly has occurred remove the paint from the pilot assembly, or replace. Fine emery cloth or asynthetic scrub pad (such as Scotch-Brite™) can be used to remove the paint from the pilot hood, electrodeand flame sensor.INSERT PILOT ASSEMBLY*Maximum inlet pressure not to exceed 13”Pressure Natural Gas(inches)Natural Gas(millibars)Propane(inches)Propane(millibars)Inlet *7”(minimum 4.5”)17.4mb(minimum 11.2mb)13”(minimum 11”)32.4mb(minimum 27.4mb)Outlet 3.5” 8.7mb 10” 24.9mbA BPILOT SCREW9.12 pilot burner adjustment9.13 flame characteristicsA BPILOT SCREWRegardless of venturi orientation, closing the airshutter will cause a more yellow flame, but can lead tocarbonization. Opening the air shutter will cause a moreblue flame, but can cause fl ame lifting from the burnerports. The flame may not appear yellow immediately;allow 15 to 30 minutes for the final fl ame colour to beestablished.AIR SHUTTER ADJUSTMENT MUST ONLY BEDONE BY A QUALIFIED INSTALLER!Fig. 2