132 System messages and MMI commands descriptionTable 17System messages displayed on the system terminal of TTY (cont’d.)Reset caused by the CPU. xx is the boot code version.Multiple unassisted power-up resets indicate card,backplane, or supply failure. Watchdog reset mayindicate firmware problem.FXPEC Reset: Power-up/Watchdog/MSL-1 Boot version: xxReset caused by the MPU. xx is the boot code version.Multiple unassisted power-up resets indicate card,backplane, or supply failure. Watchdog reset mayindicate firmware problem.Card ID: string Prints the card ID stored in the EEPROM.FXNET/FXPEC Main code version: xx {+pROBE}This message appears at the end of the boot process.TSIC Memory Mismatch . . . Rebuild OKBRSC Local Switch Memory Mismatch, IVDch = x . . . Rebuild OKHardware or firmware fault (switching mechanism).Check to see if the Fiber Superloop Network card isseated correctly in its card slot.Stuck RSIGR71 CRC. cnt = xR71 trunc. Cnt = xR71 misalign. Cnt = xR71 no resync. Cnt = xAll these messages indicate problem with R71 (RSIG)signaling. If problem persists, do selftest to identify theproblem, which may be hardware.Self-test messagesCard test started...PASSED! or FAILED!In case of selftest failure, the self-test is restarted anda message is printed to indicate the cause of failure.If the fault persists, replace the card. The systemwill output a message to identify the fault. Failedcomponent messages and their description are listedas follows:MPU confidence test failedThe basic confidence test of the MPU of the testedcard failed.MPU int mem test failed: address= addr expected= x received = yNortel Communication Server 1000Fiber Remote IPE FundamentalsNN43021-554 04.01 4 June 2010Copyright © 2007-2010 Nortel Networks. All Rights Reserved.