80 Equipment installation and configuration• defining the loadware• configuring the MMI portConfiguring fiber-optic cardsWhen the Fiber Remote IPE equipment is first installed, specify thefollowing functions:• Define the NT1P61 Fiber Superloop Network and NT1P62 FiberPeripheral Controller cards as standard NT8D04 Superloop Networkand NT8D01 Peripheral Controller cards.• Load Configuration Record Program LD 97 to configure the FiberRemote and superloop parameter data blocks.Table 9LD 97 - Configure the Fiber Remote and superloop parameter data blocksPrompt Response DescriptionFiber Remote Parameters Data BlockREQ CHG Change the Fiber Remote parametersTYPE FIRP Fiber Remote parametersSUPL 0-156 Superloop number associated with the RemoteIPE shelfNNDC 5-(7)-8 No-New-Data-Calls condition thresholdXSMN (0)–63Wall-mounted Fiber Remote IPE cabinet only.System monitor address on the Remote IPEshelf. 0 means none equipped.For floor-standing Fiber Remote IPE column,ignore this field. PKG 286 required.Superloop Parameters Data BlockREQ CHG Change superloop data blockTYPE SUPL Superloop typeSUPL 0-156 Superloop number in multiples of 4SLOT (L) R Network slot default (left) or rightSUPT FIBR Superloop type (Fiber)XPE0 x 0 3 x= Fiber Peripheral Controller card, 0= startingsegment, 3= ending segmentXPE1 Fiber Peripheral Controller card 1. Usually notequipped in Fiber Remote IPE.XPEC 1-95 Fiber Peripheral Controller card number. Thesuperloop block is built with default parameters.Nortel Communication Server 1000Fiber Remote IPE FundamentalsNN43021-554 04.01 4 June 2010Copyright © 2007-2010 Nortel Networks. All Rights Reserved.