1100 QPC513 Enhanced Serial Data Interface cardMode PortJumper socketdesignationsData communication equipment (DTE) 2 UA17 UA19Data terminal equipment (DCE) 2 UA16 UA18Table 449ESDI card RS-232-C/high-speed interface jumper settingsMode PortJumper socketdesignationsRS-232-C interface 1 UB9 UB11High-speed interface 1 UB10 UB12RS-232-C interface 2 UB16 UB18High-speed interface 2 UB17 UB19Software service changesAll of the other ESDI port operating parameters are defined in software anddownloaded to the assigned ESDI port. See Table 443 "Characteristicsof synchronous ports" (page 1093). These changes are made using theConfiguration Record program (LD 17). Instructions for the ConfigurationRecord program are found in the Software Input/Output Reference —Administration (NN43001-611).Some of the prompts that are commonly used when running theConfiguration Record program (LD 17) are shown in Table 450 "LD 17 -Serial port configuration parameters." (page 1100) These parameters mustbe set for each ports if both ports are being used.Table 450LD 17 - Serial port configuration parameters.Prompt Response DescriptionREQ: CHG Change configuration.TYPE: CFN Configuration type.IOTB YES Change input/output devices.ADAN NEW TTY xNEW PRT xDefine a new system terminal (printer) port as device x, where x= 0 to 15.CDNO 1-16 Use the ESDI card number to keep track of all ports.DENS DDEN Double density SDI paddle board.Nortel Communication Server 1000Circuit Card ReferenceNN43001-311 01.04 StandardRelease 5.0 23 May 2008Copyright © 2003-2008, Nortel Networks.