198 NT5D11 and NT5D14 Lineside T1 Interface cardsXPECAddressS1 SwitchPosition 3S1 SwitchPosition 4S1 SwitchPosition 5S1 SwitchPosition 607 Off On On On08 On Off Off Off09 On Off Off On10 On Off On Off11 On Off On On12 On On Off Off13 On On Off On14 On On On Off15 On On On OnTable 93Lineside T1 card - T1 Switch 2 (S2) dip switch settingsDip SwitchNumber Characteristic Selection1 T1 framing On = D4Off = ESF2 T1 Coding On = AMIOff = B8ZS3–5 CPE or CSU distance See Table 94 "Lineside T1 card -CPE or CSU distance dip switchsettings (Switch S2, positions 3- 5)" (page 198)6 Line processing on T1 link failure On = On-hookOff = Off-hook7 Daisy-chaining to MMI On = YesOff = No8 MMI Master or Slave On = MasterOff = SlaveTable 94Lineside T1 card - CPE or CSU distance dip switch settings (Switch S2, positions 3 - 5)DistanceS2 SwitchPosition 3S2 SwitchPosition 4S2 SwitchPosition 50–133 On Off Off134–266 Off On On267–399 Off On OffNortel Communication Server 1000Circuit Card ReferenceNN43001-311 01.04 StandardRelease 5.0 23 May 2008Copyright © 2003-2008, Nortel Networks.