306 Chapter 8 Replacing consumablesReplacing the developer — overviewReplacing the developerReplacing the developer — overviewCaution:■ Do not allow developer to get into eyes. In the event of contact with eyes,rinse eyes out with plenty of cold water and seek medical help.■ Avoid contact with the skin; wear gloves. In the event of contact with theskin, wash with plenty of cold water.■ Do not inhale developer. Avoid accumulation of dust. If, after inhalingdeveloper, you experience symptoms such as nausea, headaches ordizziness, immediately go out into the fresh air.■ Do not spill developer. You can slip on spilled developer.■ Clean up developer spill immediately. Always use an industrial vacuumcleaner with a grounded suction tube, rubber nozzle and filter set for finedust. For larger quantities, the industrial vacuum cleaner must beexplosion-proof.■ Keep developer out of the reach of children and store it away fromcontainers used for food and drink.Attention:■ - Only use approved developer (see Developer on page 297).■ Only use original, sealed developer bottles secured by an intact band.■ Do not re-use developer.■ Always store developer in a cool (< 35 oC), dry and well ventilated room.■ Never expose developer to direct heat (sunlight, heaters, etc.)Note:Only use an original, sealed developer bottle to refill the developer.Keep used developer ready for collection by Service or the contracted shippingcompany.The printing system will continue to print even when the end of the developer'sservice life has been reached.This means that the developer counter in the 'Consumable counter' menu can alsoregister negative.