![Oce VarioStream 8000 User Manual Manual pdf 403 page image](https://manuals-archive2.s3.amazonaws.com/3997372/4c5890ba485afa261c09c8d3e9ff31d8403f.jpg)
403Install photoconductor drumInstall photoconductor drumAttention:The surface of the photoconductor drum is extremely sensitive and can be easilydamaged.Avoid direct exposure to sunlight and do not touch.Note:When installing the photoconductor drum, observe the safety directives in thesection Replacing the photoconductor drum - overview on page 399.Installing the photoconductor drum[218]Proceed as follows:1. Grasp the new photoconductor drum by the handle frame and carefully re-move from the packaging.2. Note the "DRUM TYPE:" number specified on the photoconductor drumpackaging.[572]CautionRisk of damage to the cleaning blade.When inserting the photoconductor drum, ensure that the cleaning blade onthe charge corotron is not damaged.3. [573]Push in photoconductor drumto the stop point via the flangeshafts.