399Replacing the photoconductor drum - overviewReplacing the photoconductor drumReplacing the photoconductor drum - overviewCaution:■ The photoconductor drum may only be replaced by operators aftertraining or instructions from service personnel.■ When replacing the photoconductor drum, always wear the glovesprovided.Skin ailments can result from touching the photoconductor drum.If you touch the belt, wash skin thoroughly with soap and water.■ Keep photoconductor drums out of the reach of children.Attention:■ In the event that pieces of the photoconductor drum coating flake off, youmust collect all these pieces.Store old photoconductor drums and any flakes of coating in the originaldrum cartons, and keep for collection by service or the contracted shippingcompany.Photoconductor drums and collected flakes of coating require specialdisposal.■ If the photoconductor drum had only a short service life, the cause of theproblem must be identified in order to prevent further damage.■ Use only permitted photoconductor drums.■ Store new photoconductor drums in appropriate conditions:- Do not store together with flammable substances.- Store in the closed original carton in a dry environment at 15 to 25 oC .OverviewThe following procedure is for replacing the photoconductor drum:■ Removing the photoconductor drum on page 400■ Install photoconductor drum on page 403