– 79 –Chapter 4 Operation — Menu setting contents[HLG] A hybrid log gamma (HLG) curve.(Factory setting: [V-255570L1])[MASTER GAMMA]Sets the master gamma in 0.01 steps.The items that can be set are as follows.f [0.30]…[0.75](Factory setting: [0.45])[BLACK GAMMA]Sets the gamma curves of dark areas.The items that can be set are as follows.[−8]…[−1] Compresses the dark area.[OFF] Standard condition.[1]…[8] Expands the dark area.(Factory setting: [OFF])[B.GAMMA RANGE]Sets the maximum level to perform compression/expansion of dark area.The items that can be set are as follows.[1] Around 20%[2] Around 30%[3] Around 40%(Factory setting: [1])[KNEE][KNEE SW]Enables/disables operation of the knee.The items that can be set are as follows.f [ON], [OFF](Factory setting: [ON])[KNEE MODE]Sets the knee operation mode.[D RANGE] The dynamic range that can be represented is determined by the value of [KNEE SLOPE] in [KNEE].The value of dynamic range that can be represented does not change even when the value of [KNEE POINT] in [KNEE] ischanged.[PRESS] The compression rate of the signal is determined by the value of [KNEE SLOPE] in [KNEE].The value of dynamic range that can be represented will change when the value of [KNEE POINT] in [KNEE] is changed.(Factory setting: [D RANGE])[KNEE POINT]Sets the position of the knee point.The items that can be set are as follows.f [55%] … [100%] (1% steps)(Factory setting: [85%])[KNEE SLOPE]Sets the knee inclination.The items that can be set are as follows.f [0]…[100](Factory setting: [100])[HLG KNEE][KNEE SW]Enables/disables the operation of knee for HLG.The items that can be set are as follows.f [ON], [OFF](Factory setting: [OFF])