High−speed Counter/Pulse Output/ PWM Output FP09 − 209.4 Pulse Output Function9.4.3 I/O Allocation and WiringSingle pulse input driver (pulse input and directional switching input)One output point is used as a pulse output and the other output is used as a directionaloutput.The pulse output terminal, directional output terminal, and home input I/O allocation isdetermined by the channel used. For detailed information section 9.2.1Near home input is substituted by allocating the desired contact point and turning onand off the specified bit of DT9052/DT90052.For detailed information F0 (MV)Up to two driver systems can be connected.When using CH0X0X2Y0Home inputNear homeinputPulse output*Y2 Directionalswitching outputFP0Driver* The near home input specifies the desired input, such as X2.When using CH1Home inputNear homeinputPulse outputDirectionalswitching outputDriverX1X3Y1*Y3FP0* The near home input specifies the desired input, such as X3.