7.4.4 Utility—Monitor/Trace—Air Sync GroupThis utility monitors the status of CSs being synchronised with air synchronisation. CSs receive data from otherCSs that they are currently synchronised with. Current Sync CS information is displayed for IP-CSs that arein INS status.This option is only available at Installer level in On-line mode.The displayed items for the Current Sync CS of each CS are as follows:Item DescriptionCS Type Type of CS that each CS is currently synchronised with.Shelf The shelf number (or Virtual for IP-CSs) of the CS that each CS is currentlysynchronised with.Slot Slot number of the CS that each CS is currently synchronised with.Port Port number of the CS that each CS is currently synchronised with.CS / Repeater Indicates whether the CS that each CS is currently synchronised with is aCS or Repeater.CS Name Name of the CS that each CS is currently synchronised with.CS ID 12-digit ID number of the CS that each CS is currently synchronised with.Monitored Value Monitored value (dBm) of the CS that each CS is currently synchronisedwith.Monitored Level Monitored level (signal strength level) of the CS that each CS is currentlysynchronised with.Error Rate Error Rate (%) of the CS for each CS that it is currently synchronised with.To monitor the status of CSs1. From the Air Synchronisation Group Number drop-down list, select the desired Air SynchronisationGroup number.2. From the Interval Timer drop-down list, select the number of seconds between each automatic screenrefresh.3. Click Start to monitor the status of air synchronisation.Monitoring will be performed and the screen will refresh according to the specified interval.4. Click Stop to end monitoring.5. To refresh the screen manually at any time, click Refresh.6. To collect the monitored data, click Start Capture.7. Click Stop Capture to finish and save the monitored data.A dialogue box will be displayed.8. Navigate to the folder in which you want to save the file.9. Enter a file name.10. Click Save.The dialogue box will close.PC Programming Manual 1317.4.4 Utility—Monitor/Trace—Air Sync Group