Displaying System Information7-22 9161-A2-GH30-30April 1998Table 7-2. Health and Status Messages (5 of 5)Message What To DoWhat It IndicatesDevice Failyyyyyyyy The operating softwaredetects an internal error.(yyyyyyyy represents aneight-digit hexadecimal failurecode for use by servicepersonnel) This conditionclears after a reset of the unit.Contact your servicerepresentative.Module MisConfig,SlotssThe APM in slotxx is not theone specified in the NAM’sconfiguration table. 1, 21. Replace the APM with thetype of APM specified bythe configuration table.2. Change the currentconfiguration to reflect thetype of APM in the slot. Todo this, edit theconfiguration, accept theAPM, then save theconfiguration.Module Unsupported,SlotssThe NAM does not recognizethe APM. 1, 2A Dual DSX APM has beeninstalled in a Model 916x T1Access Unit.1. Check that an E&M VoiceAPM, FXS Voice APM,FXO Voice APM, Dual DSXAPM, or Sync Data APM isinstalled in Slotss.12. For Model 926x T1 AccessMux, check that there is notmore than one DSX APMinstalled (only one issupported).3. Re-download the NAMsoftware if new APMs aresupported in later releases.4. Replace the APM.5. Contact your servicerepresentative.Remove the Dual DSX APM.1ss represents physical slots.2 Does not apply to the access carrier.Self-Test Results MessagesAll self-test results messages appear in the middle column of the System andTest Status screen (see Table 7-3).