Troubleshooting9-139161-A2-GH30-30 April 1998Table 9-1 lists the alarm messages and corresponding clear messages inalphabetical order. Priority order is identified. Each alarm message contains: Date and time (month/day/year hours:minutes:seconds) that the conditionoccurred or was cleared. The user-configured device name. Alarm description. An identification of the affected interface (when applicable).Table 9-1. ASCII Alarm Messages (1 of 5)Message What It Indicates What To Do Prioritymonth/day/yearhours:minutes:seconds –An Abnormal Station Codehas been received at theOCU-DP port in slotssportp.An Abnormal StationCode from the networkDS0 is detected on thespecified OCU-DPport1. Check that thefar-end DSU isoperational.2. Check the far-endcable to the DSU.17month/day/yearhours:minutes:seconds –Alarm Cleared for AbnormalStation Code at OCU-DPport in slotss portp.Alarm condition nolonger exists.No action needed.month/day/yearhours:minutes:seconds –Alarm Indication Signal(AIS) received at theNetwork 1/Network 2Interface or at the DSX-1Interface in slotss portp.An Alarm IndicationSignal condition isdetected on thespecified Network orDSX-1 interface.Check the status ofthe far-end unit. Ifnecessary, contactnetwork provider forNetwork interface.Check the DTEattached to the DSX-1interface.6 (Net)7 (DSX-1)month/day/yearhours:minutes:seconds –Alarm Cleared for AlarmIndication Signal (AIS) atthe Network 1/Network 2)Interface or at the DSX-1Interface in slotss portp.Alarm condition nolonger exists.No action needed.month/day/yearhours:minutes:seconds –An APM Card Failure hasbeen detected for slotss.An APM card failure isdetected for theidentified slot.1. Check that the APMcard is seatedproperly.2. Contact yourservicerepresentative.11month/day/yearhours:minutes:seconds –Alarm Cleared for an APMCard Failure for slotss.Alarm condition nolonger exists.No action needed.