A-30 FieldbusesAC30 series Variable Speed InverterParameter SummaryThe following parameters are relevant to the EtherNet/IP adapter.Parameter Name No. Path Default Range WritableEtherNet IPEnable3128 Setup::Communications::Base EtherNetIP Parameters::Base Comms::EtherNetIP AdapterFALSE FALSETRUECONFIGEtherNet/IP adapter parameter. / Enables the built-in EtherNet/IP adapter.EtherNet IP Trip 3129 Setup::Communications::Base EtherNetIP Parameters::Base Comms::EtherNetIP AdapterLOSS OFCONNECTION0: DISABLED1: LOSS OFCONNECTIONCONFIGEtherNet/IP adapter parameter. / Enables the EtherNet/IP trip on loss of connection.Enumerated values:0: DISABLED the trip is disabled1: LOSS OF CONNECTION the inverter will trip on the loss of all Class 1 connectionsEtherNet IPState3130 Monitor::Communications::BaseEtherNet IPParameters::Base Comms::EtherNet IPAdapterSETUP 0: SETUP1: NW_INIT2: WAITING TOCONNECT3: CONNECTION IDLE4: CONNECTIONACTIVE5: ERROR6, 7: Reserved8: NONENEVEREtherNet/IP adapter parameter.Diagnostic indicating the state of the EtherNet/IP adapter.Enumerated values:0: SETUP EtherNet/IP adapter enabled – the inverter is in the configuration state1: NW_INIT network initialization2: WAITING TO CONNECT waiting for a Class 1 connection3: CONNECTION IDLE Class 1 connection made with scanner in Idle mode4: CONNECTION ACTIVE Class 1 connection made with scanner in Run mode5: ERROR configuration error8: NONE EtherNet/IP adapter disabled