C-116 Parameter ReferenceAC30 series Variable Speed DriveMotor NameplateSetup::Motor Control::Motor NameplateParameters::Motor Control::Motor NameplateOnly available if IM MOTOR selected in Control Mode.In this function you enter the details of the motor under control and any available motor nameplate information.Refer to Induction Motor Data parameters which are determined by the Auto Tune feature for example the Magnetising Current, StatorResistance, Leakage Inductance, Mutual Inductance and Rotor time Constant for model parameters.Note Do not attempt to control motors whose rated current is less than 25% of the drive rated current. Poor motor control orAutotune problems may occur if you do.Parameter Name No. Path Default Range Units WritableRated Motor Current 0455 Setup::Motor Control ::Motor NameplateParameters::Motor Control::MotorNameplate1.56 0.00 to 10000.00 A STOPPEDRated motor current on the name plateBase Voltage 0456 Same as PNO 455 400.00 0.00 to 1000.00 V STOPPEDThe rated motor voltage on the name plateBase Frequency 0457 Same as PNO 455 50.00 0.00 to 1000.00 Hz STOPPEDThe base motor frequency on the name plateMotor Poles 0458 Same as PNO 455 4, 2 to 1000 STOPPEDMotor poles on the nameplateNameplate Speed 0459 Same as PNO 455 1450.00 0.00 to 100000.00 RPM STOPPEDRated motor speed on the name plate