Appendix E: Hub Site SynchronizationWinLink User and Installation Guide Version 1.750 13-150Hardware InstallationHSS supports installation of up to sixteen collocated units. In additionto each unit being connected to its IDU or PoE device, the collocatedunit has an additional cable that is connected to the HSS Unit. The HSSUnit is a compact, weatherproof (IP67) connector box that is installedon the same mast as the ODUs. All collocated units connect to this boxvia CAT 5e cable. Prepared lengths are available for purchase.The HSS is supplied with ten protective covers; any port not in usemust be closed with a protective cover.Figure 13-4: HSS Interconnection UnitEnsure that the collocated units are connected in sequence from SYNC1. If an ODU is removed form the hub site, then all remaining ODUsmust be reconnected to maintain the connectivity.To connect an ODU to the HSS1. Unscrew the protective cover from the port marked SYNC 1.2. Connect the RJ-45 connector from one end of the prepared CAT 5ecable to SYNC 1.3. Connect the other end of the CAT 5e cable to the ODU connectorlabeled SYNC.4. Tighten the protective seal that is on the prepared cable over the RJ-45connector.Note