Link Configuration WizardWinLink User and Installation Guide Version 1.750 5-80Transparent/TransparentWinLink™ regenerates the clock from line clock side to Txclock on the opposite side of the link.Loop time/RecoverThe local unit receive clock is the transmit clock on both sidesof the link.Recover/Loop timeThe remote unit receive clock is the transmit clock on bothsides.Internal/RecoverThe local unit internal oscillator generates the clock while theremote unit recovers this clock.Recover/InternalThe remote unit internal oscillator generates the clock whilethe local unit recovers this clock.Note:The Line code option is used with T1 Systems.Table 5-1: TDM Clock ModesUnit Clock Mode User Equipment SideLocal Unit Remote Unit HQ side Branch side1 Transparent Transparent Internal/Recover Internal/Recover2 Loop Time Recover Internal Recover3 Recover Loop Time Recover Internal4 Internal Recover Recover Recover5 Recover Internal Recover RecoverSetting the T1 Line CodeThe T1 line code can be set as B8Zs or AMI in the TDM Parametersdialog box.The default is B8ZS.Note:This dialog box is available only when TDM service was selected in theprevious Services dialog box.