SAMSUNG DCS PROGRAMMINGTECHNICAL MANUAL SECTIONPage 190 of 287 Updated I&M May 2002MMC 709: PBX Access CodeDESCRIPTION:MMC 709 is used to program PBX codes. If the outgoing Trunk has been designated as a PBX type Trunkrather than a CO type Trunk See (MMC 401), the PBX codes are taken into account for Access Barringpurposes to ensure Access Barring operates correctly. There is a maximum of five (5) entries allowable.PROGRAM KEYSUP & DOWN Used to scroll through optionsKEYPAD Used to enter selectionsSOFT KEYS Move cursor left and rightSPK Used to store data and advance to next MMCHOLD Used to clear previous entryACTION DISPLAY1. Press TRSF 709 PBX ACCESS CODEDisplay shows 1:2. Enter in index number (eg., 3) PBX ACCESS CODEOR 3: _Press UP or DOWN key to make selectionand press RIGHT soft key to move cursor3. Enter in via dial keypad the desired PBX ACCESS CODEaccess/feature code (eg., 9) 3: 9Press RIGHT soft key to enter and returnto step 2 and enter more entries4. Press TRSF to store and exitORPress SPK to store and advance to nextMMCDEFAULT DATA: NONERELATED ITEMS: MMC 401 CO/PBX LINEMMC 702 TOLL DENY TABLEMMC 703 TOLL ALLOWANCE TABLEDCS 24, DCS 70 and DCS 200 Version 6.x softwareMMC includes “SPECIAL CODE” entries – Maximum of 10 codesSpecial codes are provided to enable correct TOLL RESTRICTION functionin the case of prefix’s dialled to enable CO FUNCTIONS.EG: 1414 AAPT toll prefix1831 PSTN CID withhold