TASCAM HS-20 8910 – Internal settings4. Deleting files on this unitDeleting the current take is possible only when playbackis stopped.Files other than the current take may always be deleted.However, since inconsistencies will occur between theunit's management files and audio files you need to usethe REBUILD function after deleting a file.o After deleting a file (while stopped if during playback/recording) use the REBUILD function when the followingREBUILD confirmation message appears.o If you do not rebuild, the following message mightappear because of the inconsistencies between the unit'smanagement files and audio files.o When rebuilding is necessary, a V mark is shown on thefollowing buttons.Touch the REBUILD button on a menu to rebuild.o File name buttons on the HOME screeno FILE LIST screen MENU buttono REBUILD button on various menus5. Adding new folders to this unit.Adding a new folder to this unit is always possible.6. Deleting folders on this unitDeleting the current folder is possible only whenplayback is stopped.Deleting other folders is always possible.7. Changing the names of files and folders on this unitThe names of files and folders on this unit can never bechanged.NOTEFTP transfer with USB flash drives is only supported whenthe unit is stopped. Do not edit, load folders, skip orotherwise operate the unit.8 Remote control (Telnet)This unit enables you to utilize remote control over theEthernet using Telnet via port 23.o Settings necessary for Telnet connectionThe setting values necessary to connect Telnet with this unitare as follows:IP Address: The IP Address of this unit is shown on theNETWORK page of the REMOTE SETUP screen.Port number: 23Password: The default password is “HS-20”.Uppercase and lowercase letters are distinguished.You can change the password with the Password[Change…] button on the NETWORK page of theREMOTE SETUP screen.o Connecting this unit with Telnet1. Press the computer enter key after connecting to thisunit with Telnet using the above IP address and portnumber.2. Enter the above password and press the enter key whenEnter Password appears on the Telnet console.3. When you have successfully logged in, "LoginSuccessful" appears on the Telnet console. Enter “exit”and press the Enter key to disconnect Telnet.NOTE• Only one Telnet connection is possible.• If EXTERNAL Control on the LOCK SETUP screen is set toLOCK, you cannot make Telnet connections.An active Telnet connection will be canceled if this is set toLOCK.• An active Telnet connection will be canceled if you changethe settings on the NETWORK page on the REMOTE SETUPscreen.• Please consult with TASCAM Customer Support for theTelnet command protocol of this unit.8 VNC (Virtual Network Computing)You can operate the system from a computer by using a VNCviewer application to display the screen shown on this unit’sLCD.You can operate the unit as follows using a mouse in a VNCviewer application.Mouse left click: Functions in the same way as touchingthe LCD of this unit.Mouse wheel click: Functions in the same way as theENTER key of this unit.Mouse wheel scroll: Functions in the same way as theDATA dial of this unit.Mouse wheel press and scroll: Functions to make coarseadjustments in the same way as when you press andturn the DATA dial of this unit (coarse mode).