wc_tx003618gb_FM10.fm64Mobile GeneratorOperation (Basler Controller)7.10 Starting and Running the GeneratorPreliminary Perform the procedure below to start and run the machine.1. Set the engine start switch (a) to the OFF position.Note: Graphic is representative only. Your machine may vary.2. Set the main circuit breaker (b) to OFF.3. Set the convenience receptacle circuit breakers (c, d) to OFF.4. Turn off all loads.5. Check position of the voltage selector switch (e) and make sure it is set for thedesired voltage output. Lock the voltage selector switch in place if desired.6. If equipped, set the idle switch (g) to the low speed position (turtle).This procedure continues on the next page.CAUTIONPossibility of injury or equipment damage. Failure to match phase, voltage, andfrequency may cause equipment connected to the generator to operate incorrectly.► When using the generator as a stand-by or substitute power supply, make surethe phase, voltage, and frequency of the generator matches that of the utilitylines or of any other power source normally used.wc_gr011540AØ HZVRBaslerDIAGNOSTICSDIAGNOSENDIAGNOSTICOSDIAGNOSTICSAUSAUSAPAGADOAPAGADOARRETARRETOFFOFFREMOTE STARTREMOTE STARTFERNSTARTFERNSTARTARRANQUE REMOTOARRANQUE REMOTODEMARRAGE ADEMARRAGE ADISTANCEDISTANCESTART / LAUFENSTART / LAUFENARRANQUE / MARCHAARRANQUE / MARCHADEMARRER / MARCHEDEMARRER / MARCHESTART / RUNSTART / RUNAUAUSSAPAGADAPAGADOOARREARRETTOFOFFFREMOTE STARREMOTE STARTTFERNSTARFERNSTARTTARRANQUE REMOTARRANQUE REMOTOODEMARRAGE ADEMARRAGE ADISTANCDISTANCEESTART / LAUFESTART / LAUFENNARRANQUE / MARCHARRANQUE / MARCHAADEMARRER / MARCHDEMARRER / MARCHEESTART / RUSTART / RUNNdcebafg