wc_tx003229gb_FM10.fm88Mobile GeneratorWorking with Basler Controller8.13 Changing the Pre-Crank Time Delay (Glow Plug Timer)Requirements Machine stopped Start switch in REMOTE STARTNote: Internal programming of the genset controller, or closed connections to aremote start switch, may cause the machine to start unexpectedly. Be prepared forthe engine to start even with the engine start switch in the REMOTE STARTposition.Background The genset controller includes a pre-crank time delay. This is the time the glowplugs will be on before the engine starts to crank. The factory setting is 5 seconds.The pre-crank time delay can be changed if desired.NOTICE: Do not set the glow plug timer to a value of more than 10. Damage to theglow plugs may occur.Procedure Perform the procedure below to change the pre-crank time delay.1. Press the right arrow button (1) to access the MAIN MENU.2. Using the up/down arrow buttons (2, 3) highlight SETTINGS. Then, press theright arrow button.3. Highlight SYSTEM PARAMS. Then, press the right arrow button.This procedure continues on the next page.