5 Operation5.9.5 Absolute Data Reception Sequence5-645.9.5 Absolute Data Reception SequenceThe sequence in which the SERVOPACK receives outputs from the absolute encoder and transmits them tohost controller is shown below.(1) Outline of Absolute DataThe serial data, pulses, etc., of the absolute encoder that are output from the SERVOPACK are output from thePAO, PBO, and PCO signals as shown below. Phase-C Output SpecificationsThe pulse width of phase C (origin pulse) changes depending on the encoder output pulse (Pn212), becomingthe same width as phase A.The output timing is one of the following.• Synchronized with the rising edge of phase A• Synchronized with the falling edge of phase A• Synchronized with the rising edge of phase B• Synchronized with the falling edge of phase BNote: When host controller receives the data of absolute encoder, do not perform counter reset using the output of PCOsignal.Signal Name Status ContentsPAO At initialization Rotational serial dataInitial incremental pulsesNormal Operations Incremental pulsesPBO At initialization Initial incremental pulsesNormal Operations Incremental pulsesPCO Always Origin pulsesENCCN1/SENPAOPBOPCOCN2SerialdataSerial data→pulse conversionHostcontroller SERVOPACKDividingcircuit(Pn212)Analog