6 Option Drive ParametersYASKAWA SIEP YEACOM 06 V1000 Option PROFINET SI-EP3/V Technical Manual 226 Option Drive ParametersBefore starting network communications, verify proper setting of drive parameters in Table 6 using the drive digitaloperator.Table 6 Parameter SettingsNo. Name Description Defaultb1-01<1> Frequency Reference SelectionSelects the frequency reference input source.0: Operator - Digital preset speed d1-01 to d1-171: Terminals - Analog input terminal A1 or A22: MEMOBUS/Modbus communications3: Option PCB4: Pulse Input (Terminal RP)1(Set to 3 forPROFINET)b1-02<1> Run Command SelectionSelects the run command input source.0: Digital Operator - RUN and STOP keys1: Digital input terminals S1 to S72: MEMOBUS/Modbus communications3: Option PCB1(Set to 3 forPROFINET)F6-01 Operation Selection afterCommunications ErrorDetermines drive response when a bUS error is detected duringcommunications with the option.0: Ramp to Stop1: Coast to Stop2: Fast-Stop3: Alarm Only <2>1F6-02 External Fault DetectionConditions (EF0)Sets the condition for external fault detection (EF0).0: Always detected1: Detected only during operation0F6-03Stopping Method for ExternalFault from CommunicationOption BoardDetermines drive response for external fault input (EF0) detection duringcommunication.0: Ramp to Stop1: Coast to Stop2: Fast-Stop3: Alarm Only <2>1F6-07<3>NetRef/ComRef SelectionFunction0: Multi-step speed reference disabled1: Multi-step speed reference allowed 1F6-08<3>Reset Communication RelatedParametersDetermines if communication-related parameters F6- and F7- areset back to original default values when the drive is initialized usingparameter A1-03.0: Do not reset F6- and F7- parameters1: Reset F6- and F7- parametersNote: Setting this parameter does not affect communication-relatedparameters.0F7-01 toF7-04 IP Address Sets static IP address of the SI-EP3/V option when parameter F7-13=0.Note: Parameter F7-01 sets the most significant octet. 192 168 1 20F7-05 toF7-08 Subnet Mask Sets static Subnet Mask of network connection.Note: Parameter F7-05 sets the most significant octet 255 255 255 0F7-09 toF7-12 Gateway Address Sets static Gateway address of network connection.Note: Parameter F7-09 sets the most significant octet. 192 168 1 1F7-13 Address Mode at StartupSelects how the option address is set.0: Static2: DCP2F7-14 Duplex Mode SelectionSelects duplex mode setting.0: Half duplex forced1: Auto-negotiate duplex mode and communication speed2: Full duplex forced1 <4>F7-15 Communication SpeedSelectionSets the communication speed.10: 10 Mbps100: 100 Mbps10