<6> Default setting value is dependent on parameter o2-04, Drive Model Selection.<7> Parameter ignored when E1-11, Motor 1 Mid Output Frequency 2, and E1-12, Motor 1 Mid Output Frequency Voltage 2, are set to 0.0.<8> When setting motor parameters, the motor rated current must be set to a value greater than the motor no-load current (E2-01 > E2-03).<9> Display is in the following units: BA0001 to BA0018, 2A0001 to 2A0040, and 4A0001 to 4A0023: 0.01 A units.2A0056 to 2A0069, 4A0031 to 4A0038: 0.1 A units.<10> Default setting value is dependent on parameter o2-04, Drive Model Selection and C6-01, Drive Duty Selection.<11> Setting range becomes 0.00 to 130.00 for drives 0.2 kW and smaller.<12> Default setting depends on the control mode for motor 2 set in parameter E3-01. The given value is for V/f Control.<13> Parameter ignored when E3-11, Motor 2 Mid Output Frequency 2, and E3-12, Motor 2 Mid Output Frequency Voltage 2, are set to 0.<14> Parameter can be changed during Run.<15> If using a Yaskawa SMRA Series SPM Motor, the default setting is 1800 r/min.<16> Default setting value is dependent on parameter A1-06. This setting value is 0 when A1-06 = 0, and 1 when A1-06 ≠ 0.<17> Default setting is determined by drive software version.PRG: 1018 and later: 0.0 to 6500.0 mV/(r/min)PRG: 1017 and earlier: 0.0 to 2000.0 mV/(r/min)<18> Available in drive software versions PRG: 1022 and later.<19> The default value is for the following localized drives: Japan (Model code: CIMR-VAoA) and Asia (Model code: CIMR-VToA) .Refer toChina Localized Drive Default Values on page 381 for the default values of China localized (Model code: CIMR-VBoA) drives.B.2 Parameter Table346 YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual