n Drive Software Version PRG: 1018 and LaterTable B.14 400 V, 1750 rpm Type Yaskawa SSR1 Series MotorPar. Description Unit Default SettingsE5-01Motor Code − 1232 1233 1235 1236 1238 123A 123B 123D 123E 123FVoltage Class − 400 Vac 400 Vac 400 Vac 400 Vac 400 Vac 400 Vac 400 Vac 400 Vac 400 Vac 400 VacRated Power − 0.4 kW 0.75 kW 1.5 kW 2.2 kW 3.7 kW 5.5 kW 7.5 kW 11 kW 15 kW 18 kWRated Speed r/min 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750E5-02 Motor Rated Power kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5E5-03 Motor Rated Current A 0.89 1.56 2.81 4.27 7.08 10.31 13.65 20.7 27.5 33.4E5-04 Motor Pole Number – 6 6 6 6 6 6 6 6 6 6E5-05 Motor WindingResistance Ω 25.370 9.136 6.010 3.297 1.798 0.982 0.786 0.349 0.272 0.207E5-06 d-Axis Inductance mH 169.00 92.08 67.71 34.40 32.93 22.7 16.49 13.17 10.30 8.72E5-07 q-Axis Inductance mH 197.5 119.56 81.71 54.00 37.7 26.8 23.46 15.60 12.77 11.22E5-09 Induction VoltageConstant 1 mVs/rad 392.6 440.6 478.3 466.3 478.8 478.1 520.0 481.5 498.8 509.5E5-24 Induction VoltageConstant 2mV/(r/min) 0 0 0 0 0 0 0 0 0 0E1-04 Maximum OutputFrequency Hz 87.5 87.5 87.5 87.5 87.5 87.5 87.5 87.5 87.5 87.5E1-05 Maximum OutputVoltage V 380 380 380 380 380 380 380 380 380 380E1-06 Base Frequency Hz 87.5 87.5 87.5 87.5 87.5 87.5 87.5 87.5 87.5 87.5E1-09 Minimum OutputFrequency Hz 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4L3-24<1>Motor AccelerationTime for InertiaCalculationss 0.092 0.076 0.051 0.066 0.075 0.083 0.077 0.084 0.102 0.101n8-49d-Axis Current forHigh-EfficiencyControl% –8.6 –11.5 –10.3 –19.8 –8.5 –11 –18.6 –12.5 –15.5 –17.9<1> Default setting value is dependent on parameter o2-04, Drive Model Selection.B.7 Parameters that Change with the Motor Code Selection394 YASKAWA ELECTRIC SIEP C710606 16C YASKAWA AC Drive – V1000 Technical Manual