3Com® VCX V7111 VoIP Gateway User Guide 447Probable Cause: resourceAtOrNearingCapacity (43)Alarm Text: Active alarm table overflowStatus Changes:Condition: Too many alarms to fit in the active alarm tableAlarm status: MajorCondition: After raiseAlarm status: Status stays major until reboot. A clear trap is not sent.Note: The status stays major until reboot as it denotes a possible loss of informationuntil the next reboot. If an alarm is raised when the table is full, it is possiblethat the alarm is active, but does not appear in the active alarm table.Corrective Action: Some alarm information may have been lost, but the ability of the device toperform its basic operations has not been impacted. A reboot is the only way tocompletely clear a problem with the active alarm table. Contact your first-levelgroup.Component: EthernetLink#0The source varbind text for all the alarms under this component isBoard#>/EthernetLink#0 where n is the slot number. This trap relates to the Ethernet LinkModule (the #0 numbering does not apply to the physical Ethernet link).Table 127 acBoardEthernetLinkAlarm Alarm TrapAlarm: acBoardEthernetLinkAlarmOID: 1.3.6.1.4.1.5003.9.10.1.21.2.0.10Default Severity: CriticalEvent Type: equipmentAlarmProbable Cause: underlyingResourceUnavailable (56)Alarm Text: Ethernet link alarm: Status Changes:Condition: Fault on single interfaceAlarm status: major value: Redundant link is downCondition: Fault on both interfacesAlarm status: critical value: No Ethernet link