448 3Com® VCX V7111 VoIP Gateway User GuideCondition: Both interfaces are operationalAlarm status: clearedCorrective Action: Ensure that both Ethernet cables are plugged into the back of the system.Inspect the systems Ethernet link lights to determine which interface is failing.Reconnect the cable or fix the network problemLog Traps (Notifications)This section details traps that are not alarms. These traps are sent with the severity varbindvalue of indeterminate. These traps do not clear, they do not appear in the alarm history oractive tables. One log trap that does send clear isacPerformanceMonitoringThresholdCrossing.Table 128 acKeepAlive Log TrapTrap: acKeepAliveOID: 1.3.6.1.4.1.5003.9.10.1.21.2.0.16Default Severity: IndeterminateEvent Type: other (0)Probable Cause: other (0)Trap Text: Keep alive trapStatus Changes:Condition: The STUN client in is enabled and identified a NAT device or does not locatethe STUN server.The ini file contains the following line: SendKeepAliveTrap=1Trap status: Trap is sentNote: Keep-alive is sent every 9/10 of the time defined in the parameterNatBindingDefaultTimeout.Table 129 acPerformanceMonitoringThresholdCrossing Log TrapTrap: acPerformanceMonitoringThresholdCrossingOID: 1.3.6.1.4.1.5003.9.10.1.21.2.0.27Default Severity: IndeterminateEvent Type: other (0)Probable Cause: other (0)Trap Text: "Performance: Threshold trap was set”, with source = name of performancecounter which caused the trapStatus Changes: